AN315 - Anesthesia Machines
  • With 5.5" SNT screen. Mounted on 4 castors. 2 front castors with brakes.
  • With 2 big drawers
  • Handle for easy maneuvering.
  • Aluminium alloy rail frame. With durable and non-corrosive stainless steel platform.
  • Equipped with high precise Anesthesia Vaporizer (with temperature, flow and pressure compensation function).
  • The agent output is continuous, stable & precise.
  • The agent type: Isoflurane OR Enflurane.
  • With independent Anesthesia Ventilator, the ventilator frame is moulded and height can be adjusted. The ventilator can display P-t and V-t wave-form at the same time.
  • Classical CO2 circle absorber with 2 canisters for low resistance and minimum gas leakage.
  • Fresh gas outlet is in front of frame for the user to easily connect Jackson-Rees circuit.
Optional : O2, N2O Yoke device. When main gas supply is fails, the backup gas supply starts.Optional : O2, N2O Yoke device. When main gas supply is fails, the backup gas supply starts.
Feature :
Patient type : Adult, Pediatric Driven mode : Pneumatically driven electronically controlled
Mode : Semi-open, Semi-closed or closed system
Anesthetic vaporizer : One high precise Vaporizers
Power supply : 220V±10%, 50Hz±1Hz
Power consumption : <50W
Internal battery : DC12V (over 2 hours)

Anesthesia Ventilator Specification :
Respiration mode : IPPV, SIMV, SIGH, MANUAL
Waveform : P-t, V-t
Tidal Volume : 50 ~ 1600ml
Respiratory frequency : 1 to 65 BPM
I: E ratio: 8: 1~1: 8
Alarm parameters: High pressure alarm
Low pressure alarm
O2 source failure alarm
AC power failure alarm
High pressure alarm limit : 20~60CMH2O
Low pressure alarm limit : 0~20CMH2O
Monitor parameters : Tidal volume, MV, Ppeak, PEEP, respiratory frequency, I: E ratio, Airway pressure
Safety valve pressure limit : 6 Kpa
Good air tightness, high reliability and minor respiration impedance

Main Unit :
Circle absorber : Compact circle absorber
Flow meter : O2, N2O four-tube flow meter
O2 tube: 0L/min~1L/min~10L/min
N2O tube: 0L/min~1L/min~10L/min
O2 and N2O Linkage Device: Adjust O2 and N2O in proportion ( keep O2 concentration not lower than 25% )
Oxygen Flush : 25L/min ~ 75L/min
Gas source pressure : O2: 0.25 ~ 0.65Mpa
N2O: 0.25~ 0.65Mpa
Gauge : Two gauges, N2O, O2

They have been A+ in quality, pricing and after sales service...



Quick Response :


Meet us at:
  • Arab Health 2018
  • 29th Jan to 01st Feb, 2018
  • at Dubai International Convention and Exhibition Centre, Dubai, U.A.E.
Fix Appointment
  • AAOS 2018
  • 6th to 10th March, 2018
  • at New Orleans, Louisiana, USA.
Fix Appointment
  • Africa Health 2018
  • 29th to 31st May, 2018
  • at Gallagher Convention Centre, Midrand, Johannesburg, South Africa.
Fix Appointment
  • FIME Show 2018
  • 7th to 9th Aug., 2018
  • at Orange County Convention Center, Orlando, Florid, USA.
Fix Appointment


View All Exhibitions         

Exhibitions     |     Send Query
Orthopaedic Implants

Anesthesia Machines with CO2 /Multi parameter/Anesthesia Depth Monitor

AN315

Manufacturer Suppliers

Anaesthesia Equipments & Products