The NET anesthesia machine are used by anesthesiologists, nurse anesthetists to support the administration of anesthesia. It is designed to provide an accurate and continuous supply of medical gases (such as oxygen and nitrous oxide), which are mixed with an accurate concentration of anaesthetic vapour (such as isoflurane), and then delivered to the patient at a safe pressure and flow.



  • With LED screen. Mounted on 4 castors. 2 front castors with brakes.
  • With 2 big drawers . Handle for easy maneuvering
  • Epoxy painted high quality mild steel frame.
  • Equipped with Anesthesia Vaporizer.
  • Agent type: Isoflurane, Enflurane, Halothane.
  • Classical CO2 circle absorber with 1 canister
  • With necessary monitoring and alarm function, to ensure the operational safety.
Feature :
Application: Adult, Pediatric
Driven mode: Pneumatically driven electronically controlled
Mode: Semi-open, Semi-closed or closed system
Anesthetic vaporizer: One vaporizer

Anesthesia Ventilator Specification :
Display : High Power LED display
Ventilation mode : IPPV and Manual mode
Tidal Volume : 50 ~ 1600ml
Breath frequency : 1 ~ 90BPM
I: E ratio: 4: 1 ~ 1: 6
Monitor parameter Tidal volume, Breath frequency, MV, airway pressure.
Alarm MV high alarm, MV low alarm
TV high alarm, TV low alarm

Main Unit :
Circle absorber : Compact circle absorber
Bellow : 50 ~ 1600ml
Oxygen Flush : 25L/min ~ 75L/min
Flow meter : O2, N2O two-tube flowmeter
O2 tube: 0L/min ~ 10L/min
N2O tube: 0L/min ~ 10L/min
O2 and N2O linkage device
Adjust O2 and N2O in proportion ( keep O2 concentration not lower than 25% )
Gas source pressure : O2: 0.25 ~ 0.65Mpa
N2O: 0.25~ 0.65Mpa
Gauge : 2 units, one N2O, one O2

Item Code : Type Anesthesia machine with LED Screen
   
AN305 Same as AN300 but with Classical CO2 circle absorber with 2 canisters
Fresh gas outlet is in front of frame for the user to easily connect Jackson-Rees circuit. General gas switch is in front of frame
Flow meter : O2, two-tube flowmeter
O2 tube: 0L/min ~ 10L/min  ~ 10L/min
Gas source pressure : O2: 0.25 ~ 0.65Mpa
Gauge : 1 unit, one O2
  • With 5.5" SNT screen. Mounted on 4 castors. 2 front castors with brakes.
  • With 2 big drawers.
  • Handle for easy maneuvering.
  • Epoxy painted high quality mild steel frame.
  • Equipped with High precise Anesthesia Vaporizer (with temperature, flow and pressure compensation function).
  • The agent output is continuous, stable & precise. The agent type: Isoflurane, Enflurane, Halothane, Sevoflurane
  • Anesthesia ventilator with IPPV and SIMV mode. The ventilator can display P-t and V-t wave-form at the same time.
  • Necessary monitoring and alarm function to ensure operational safety.
  • Classical CO2 circle absorber with 2 canisters for low resistance and minimum gas leakage.
  • Optional : O2, N2O Yoke device. When main gas supply fails, the backup gas supply starts.
Feature :
Patient type : Adult, Pediatric
Driven mode : Pneumatically driven electronically controlled
Mode : Semi-open, Semi-closed or Closed system
Anesthetic vaporizer : One vaporizer
Power supply : 220V+/-10%, 50Hz+/-1Hz
Power consumption : Not more than 50W
Internal battery : DC12V (over 4 working hours)

Anesthesia Ventilator Specification :
Respiration mode : IPPV, SIMV, SIGH, MANUAL
Waveform : P-t, V-t
Tidal volume : 50ml~1600ml
Respiratory frequency : 1~65 BPM / I: E ratio: 8: 1~1: 8
Alarm parameters : High pressure alarm, Low pressure alarm, O2 source failure alarm
High pressure alarm limit: 20~60CMH2O / Low pressure alarm limit: 0~20CMH2O
Monitor parameters : Tidal volume, MV, Ppeak, PEEP, respiratory frequency, I: E ratio
Safety valve pressure limit : 6 Kpa

Main Unit :
Circle absorber : Compact Circle absorber Bellow : 0 ~ 1600ml
Flow meter : O2, N2O four-tube flowmeter
O2 tube: 0L/min~1L/min~10L/min
N2O tube: 0L/min~1L/min~10L/min
O2 and N2O linkage device
Adjust O2 and N2O in proportion ( keep O2 concentration not lower than 25% )
Oxygen Flush : 25L/min ~ 75L/min
Gas source pressure : O2: 0.25 ~ 0.65Mpa
N2O: 0.25~ 0.65Mpa
Gauge : 2 units, one N2O, one O2

  • With 5.5" SNT screen. Mounted on 4 castors. 2 front castors with brakes.
  • With 1 safety lock and 2 big drawers
  • Handle for easy maneuvering.
  • Aluminium alloy rail frame. With durable and non-corrosive stainless steel platform.
  • Equipped with high precise Anesthesia Vaporizer (with temperature, flow and pressure compensation function).
  • The agent output is continuous, stable & precise.
  • The agent type: Isoflurane, Enflurane.
  • With independent Anesthesia Ventilator, the ventilator frame is moulded and height can be adjusted. The ventilator can display P-t and V-t wave-form at the same time.
  • Classical CO2 circle absorber with 2 canisters for low resistance and minimum gas leakage.
  • Fresh gas outlet is in front of frame for the user to easily connect Jackson-Rees circuit.
  • With upgraded functions, eg, CO2 Monitor, Multi-parameter monitor, Anesthesia depth monitor, etc.
  • Optional : O2, N2O Yoke device. When main gas supply is fails, the backup gas supply starts.
Feature :
Patient type : Adult, Pediatric Driven mode : Pneumatically driven electronically controlled
Mode : Semi-open, Semi-closed or closed system
Anesthetic vaporizer : Two high precise Vaporizers
Power supply : 220V±10%, 50Hz±1Hz
Power consumption : <50W
Internal battery : DC12V (over 2 hours)

Anesthesia Ventilator Specification :
Respiration mode : IPPV, SIMV, SIGH, MANUAL
Waveform : P-t, V-t
Tidal Volume : 50 ~ 1600ml
Respiratory frequency : 1 to 65 BPM
I: E ratio: 8: 1~1: 8
Alarm parameters: High pressure alarm
Low pressure alarm
O2 source failure alarm
AC power failure alarm
High pressure alarm limit : 20~60CMH2O
Low pressure alarm limit : 0~20CMH2O
Monitor parameters : Tidal volume, MV, Ppeak, PEEP, respiratory frequency, I: E ratio, Airway pressure
Safety valve pressure limit : 6 Kpa
Good air tightness, high reliability and minor respiration impedance

Main Unit :
Circle absorber : Compact circle absorber
Flow meter : O2, N2O four-tube flow meter
O2 tube: 0L/min~1L/min~10L/min
N2O tube: 0L/min~1L/min~10L/min
O2 and N2O Linkage Device: Adjust O2 and N2O in proportion ( keep O2 concentration not lower than 25% )
Oxygen Flush : 25L/min ~ 75L/min
Gas source pressure : O2: 0.25 ~ 0.65Mpa
N2O: 0.25~ 0.65Mpa
Gauge : Two gauges, N2O, O2
  • With 10.4 TFT color screen.
  • Mounted on 4 castors. 2 front castors with brakes.
  • With 2 big drawers.
  • Handle for easy maneuvering.
  • Epoxy painted high quality mild steel frame.
  • Equipped with Two high precise Anesthesia Vaporizer (with temperature, flow and pressure compensation function).
  • The agent output is continuous, stable & precise.
  • The agent type: Isoflurane, Enflurane, Halothane, Sevoflurane.
  • Classical CO2 circle absorber with 2 canisters for low resistance and minimum gas leakage.
  • Optional: O2, N2O Yoke device. When main gas supply is fails, the Backup gas supply starts.
Features :
Application : Adult, Pediatric
Driven mode : Pneumatically driven electronically controlled
Mode : Semi-open, Semi-closed or closed system
Anesthetic vaporizer : Two high precise vaporizers
Power supply : 220V±10%, 50Hz ±1Hz
110V±10%, 60Hz ±1Hz
Internal battery : DC12V (over 4 working hours)

Anesthesia Ventilator Specification :
Waveform : P-t, F-t
Tidal Volume : 50ml ~ 1600ml
Respiratory frequency : 1 ~ 65 BPM
I: E ratio: 4: 1~1: 4
Inspiration pause : 0~55%Ti
Inspiration Pressure : 1~60cmH2O
Trigger Pressure :

-20~20cmH2O

Monitor parameters : O2 concentration, MV, Respiratory frequency, Tidal volume,
Ppeak, I:E ratio, Pmean, etc..

Pressure alarm setting :

High pressure alarm set 1~60cmH2O

Low pressure alarm set 0~20cmH2O

O2 concentration alarm setting:

high 21~99%

low 21~50%

MV alarm setting :

MV high alarm set 10~99L/min

MV low alarm set 0~40L/min


Main Unit :
Circle absorber : Compact circle absorber
Flow meter : O2, N2O four-tube flow meter
O2 tube: 0L/min~1L/min~10L/min
N2O tube: 0L/min~1L/min~10L/min
O2 and N2O linkage device, keep oxygen concentration over 25%
Oxygen Flush : 25L/min ~ 75L/min
Gas source pressure : O2: 0.25MPa ~ 0.65MPa
N2O: 0.25MPa ~ 0.65MPa
Gauge : 4 units, 2×N2O, 2×O2
  • With 10.4 TFT color screen
  • Mounted on 4 castors. 2 front castors with brakes.
  • With 1 safety lock and 3 big drawers.
  • Handle for easy maneuvering.
  • Aluminium alloy rail frame. With durable and non-corrosive stainless steel platform.
  • Equipped with high precise Anesthesia Vaporizer (with temperature, flow and pressure compensation function). The agent output is continuous, stable & precise.
  • The agent type: Isoflurane, Enflurane, Halothane, Sevoflurane.
  • With Volume & pressure ventilation modes.
  • Classical CO2 circle absorber with 2 canisters for low resistance and minimum gas leakage.
  • Fresh gas outlet is in front of frame for the user to easily connect Jackson-Rees circuit.
  • With upgraded with functions, eg, CO2 Monitor, Multi-parameter monitor, Anesthesia depth monitor, etc.
  • Working interfaces for adult and pediatric are separated; the doctor can choose interface according to patient type.
  • Optional: O2, N22 Yoke device. When main gas supply is fails, The backup gas supply starts.
Features :
Application : Adult, Pediatric
Driven mode : Pneumatically driven electronically controlled
Mode : Semi-open, Semi-closed or closed system
Anesthetic vaporizer : Two high precise vaporizers, Isoflurane, Enflurane, Halothane, Sevoflurane.
Power supply : 220V±10%, 50Hz ±1Hz
Internal battery : DC12V (over 4 working hours)
Fresh gas outlet is in front of frame

Anesthesia Ventilator :
Respiration mode : IPPV, VCV, PCV, SIMV, SIGH, MANUAL, STANDBY, DEMO
Waveform : P-t, F-t, V-t, F-v, V-p
Tidal Volume : 20~1600ml
Respiratory frequency : 1 ~ 65 BPM
I: E ratio: 4: 1~1: 4
Inspiration pause : 0~55%Ti
Inspiration Pressure : 1~60cmH2O
Trigger Pressure :

-20~20cmH2O

Monitoring parameters : O2 concentration, MV, Respiratory frequency, Tidal volume, Ppeak, PEEP, I: E ratio, Pmean, etc.
Alarm parameters : High pressure alarm, low pressure alarm, O2 concentration alarm, MV alarm, O2 source failure alarm, AC power failure alarm, etc.

Pressure alarm setting :

High pressure alarm set 1~60cmH2O

Low pressure alarm set 0~20cmH2O

O2 concentration alarm setting:

high 21~99%

low 21~50%

MV alarm setting :

MV high alarm set 10~99L/min

MV low alarm set 0~40L/min


Main Unit :
Circle absorber : Compact circle absorber
Flow meter : Five~tube flow meter
O2 tube: 0L/min~1L/min~10L/min.
N2O tube: 0L/min~1L/min~10L/min.
Air tube: 0L/min~10L/min
O2 and N2O Linkage Device
Keep oxygen concentration over 25%
Oxygen Flush : 25L/min ~ 75L/min
Gas source pressure : O2: 0.25Mpa ~ 0.65Mpa
N2O: 0.25Mpa ~ 0.65Mpa
Air: 0.25Mpa ~ 0.65Mpa
Gauge : 4 units, 2 x O2, N2 O, Air.

They have been A+ in quality, pricing and after sales service...




Quick Response :


Meet us at:
  • Africa Health 2014
  • 29th to 31st May, 2014 at
  • Gallagher Convention Centre.
  • Midrand, Johannesburg, South Africa.
  • Booth No. 3G20
Fix Appointment
  • FIME 2014
  • 6th to 8th Aug. 2014 at
  • Miami Beach Convention Center, Miami Beach, Florida, USA.
  • Booth No. 900
Fix Appointment
  • MEDICA 2014
  • 12th to 15th Nov, 2014 at
  • Düsseldorf, Germany
Fix Appointment
  • ARAB HEALTH 2015
  • 26 to 29 Jan, 2015 at
  • Dubai International Convention & Exhibition Centre
  • Dubai, U.A.E.
Fix Appointment


View All Exhibitions         

Exhibitions     |     Send Query
Orthopaedic Implants

Anaesthesia Machine

Anaesthesia Machine Manufacturer

Anaesthesia Machine Suppliers

Anaesthetic Machines