    Specifications :
  • High resolution 12.1" color TFT display
  • Lightweight, compact and portable
  • ECG, SPO2, NIBP, RESP, 2-TEMP, PR
  • Optional : 2-IBP, ETCO2, And thermal printer
  • Built-in rechargeable lithium battery
  • ECG waveforms of 7-leads display on the same screen
  • 72-hours graphic and tabular trends of all parameters
  • 72 alarm events of all parameters recall
  • 32 seconds full-disclosure waveform review
  • 500 NIBP measurement data storage and recall
  • Data and waveforms color be adjustable
  • Arrhythmia analysis and S-T segment analysis
  • Suitable for adult, pediatric and neonatal patient

  • Standard:
    NIBP:
  • Method: Oscillometry
  • Modes: Manual/Auto/Continuous
  • Auto measure time: Adjustable
  • Measurement rang: 10-270mmHg

  • ECG:
  • Lead mode: 3-lead or 5-lead
  • Lead selection: I; II; III; avR; avL; avF; V
  •     Heart rate range: Adult:15-300bpm;Pediatric/Neonatal:15-300bpm
  • ECG waveform: 2 channels
  • Accuracy: ± 1 bpm or ±1%
  • S-T segment detection Measurement rang: -0.2mv~2.0mv
  • Alarm: Yes, audible and visual alarm, alarm events review
  • High resolution 12.1"color TFT display
  • Lightweight, compact and portable
  • ECG, APO2, NIBP, RESP, 2-TEMP, PR
  • Optional:2-IBP, ETCO2, And thermal printer
  • Built-in rechargeable lithium battery
  • ECG waveforms of 7-leads display on the same screen
  • 72-hours graphic and tabular trends of all parameters
  • 72 alarm events of all parameters recall
  • 32 seconds full-disclosure waveform review
  • 500 NIBP measurement date can be storage and recall
  • Date and waveforms color be adjustable
  • Arrhythmia analysis and S-T segment analysis
  • Suitable for adult, pediatric and neonatal patient

  • SPO2
  • Measurement range:0-100%
  • Accyracy:70-100%, ±2% 0-69%,upspecified

  • Pulse rate
  • Range:20-254bpm
  • Accuracy: ±3bpm

  • Respiration
  • Method: RA-LL impedance
  • Range: Adult: 0-120rpm;pediatric/neonatal:0-150rpm
  • Apnca alarm Yes

  • Temperature
  • Range:0-50℃
  • Apnca: 0.1℃
  • Channel:Dual-Channel
    Specifications :
  • 8" TFT, led backlight , 800x480 pixels.
  • Visual and Audio alarms, adjustable.
  • Patient management, name and age and id.
  • Network with Central Station Software
  • Audio volume adjustable from 1 ~ 8 level.
  • Multi-language options: German, French, Italian, Turkish
  • Built-in removable and rechargeable lithium battery
  • UI with both Keypad and Touch Screen operation.
  • Memory: Built-in memory or miniSD Memory card. Store more than 1000 pieces of archive
  • Powerful data storage and management, Trend graph, Trend table, etc.
  • Arrhythmia analysis and S-T segment analysis.
  • ECG
  • Lead mode: 3-lead or 5-lead
  • HR range: 15 ~ 300 bpm
  • Accuracy: ±2bpm or ±2%, which is greater
  • NIBP
  • Method: Oscillometry
  • Mode: Manual/Auto/Continuous
  • Measurement Range: 25 ~ 260mmHg
  • SPO2
  • Measurement Range: 0 ~ 100%
  • Accuracy: ±2%(70%~100%)
  • 0% ~ 69% unspecified
  • Pulse Rate
  • Measurement Range: 25 ~ 250 bpm
  • Accuracy:±3 bpm
  • Dimension: 210 x 130 x 210mm
  • Net weight: 2.3KG
    Specifications/Details :
  • 7" TFT, touch screen, led backlight , 800x480 pixels.
  • Visual and Audio alarms, adjustable.
  • Patient management, name and age and id.
  • Network with Central Station Software
  • Audio volume adjustable 1 ~ 8 level.
  • Multi-language options: German, French, Italian, Turkish
  • Built-in removable and rechargeable lithium battery
  • UI with both Keypad and and Touch Screen operation.
  • Memory: Built-in memory or miniSD Memory card. Store more than 1000 pieces of archive
  • Powerful data storage and management, Trend graph, Trend table, etc.
  • Arrhythmia analysis and S-T segment analysis.
  • ECG
  • Lead mode:3-lead or 5-lead
  • HR range:15 ~ 300 bpm
  • Accuracy:±2bpm or ±2%, which is greater
  • NIBP
  • Method: Oscillometry
  • Mode: Manual / Auto / Continuous
  • Measurement Range:25 ~ 260mmHg
  • SPO2
  • Measurement Range: 0 ~ 100%
  • Accuracy: ±2%(70%~100%)
  • 0% ~ 69% unspecified
  • Pulse Rate
  • Measurement Range: 25 ~ 250 bpm
  • Accuracy: ±3 bpm
  • Dimension: 191 x 160 x 244(mm)
  • Net weight: 2.1KG
    Technical Parameters
  • Input circuit: Floating
  • Calibrating Voltage :1mV
  • Input current: <100nA
  • CMRR: >103dB
  • A/D: 12bit
  • Frequency Response: 0.05Hz--150Hz
  • Filter: AC 50/60Hz EMG: 35-4Hz
  • Skin Voltage Tolerance: ?00mV
  • Sensitivity Setting 5, 10, 20mm/mV, conversion deviation?%
  • Noisy Level: ?5Vp-p
  • Safety standard: IEC class I, type CF
  • Lead selection: Automatic and Manual
  • Operation mode: Automatic and Manual
  • Display: LCD 160*96 visual size: 34*60
  • Recording system: Thermal-array printing
  • Power supply: AC220V?0% DC 7.4 lithium battery
  • Size:190*90*40
  • Weight: About 800g
    Features:
  • High-resolution thermal printing array system
  • Frequency response is as high as 150Hz
  • Capable of printing continuously on channel trace and annotations including lead mark and parameter such as sensitivity, paper speed and filter operation status
  • High resolution digital filter inhibits baseline drift without affecting ECG waveform
  • One-touch operation
  • Concept of floating input circuit meets IEC safety standard
  • Rechargeable battery supporting more than 50 patient examinations
  • Lead Standard: 12 leads

Specification:

Input Circuit Floating; Protection against Defibrillator effect
Lead Standard 12 Leads, Lead change automatically <10μA
Patient Current Leakage
Input Impedance ≥10ΜΩ 
Calibrating Voltage 1mV±3%
A/D Conversion  12 bit
Frequency Response  0.05Hz~150Hz (IEC)
Time Constant  >3.2seconds
CMRR >80dB; >100dB (with filter)
EMG Filter  35Hz (-3dB) / 25Hz (-3dB)
Sensitivity 1/2, 1, 2 (cm/mV), Conversion Deviation≤5%
Recording System Thermal-array
8 dots/mm ( vertical ) 
16 dots/mm ( horizontal, 25mm/sec )
Paper Speed  25, 50mm/s±3%
Recording Paper  50mm,20m, high-speed roll
Input Circuit Current   ≤50nA
Safety Standard IEC class I, type CF
Power Supply AC: 220V / 110V, 50/60Hz
DC: 12V rechargeable battery
Skin Voltage Tolerance ±300mV
Noise Level <15uVp-p
Dimensions 310mm×230mm×70mm 
Dimension of Packing 400mm×280mm×160mm
Weight 2.75kg
    Specifications :
  • 3.5'' TFT screen
  • 12 leads simultaneous display
  • Thermal printing system
  • Power supply both AC and DC
  • High capacity built-in lithium rechargeable battery
  • Battery power supports continually record 150 pieces of ECG
  • Built-in Database
  • Store more than 1000 pieces of archive
  • Digital signal processor for filter
  • Auto-measurement,auto-analysis and auto interpretation functions
  • Lead:Standard 12 leads
  • Patient leak current:<10uA
  • Input impedance:>=50M
  • Frequency response:0.05Hz-150Hz(-3dB
  • )
  • Time constant:Time constant>3.2s
  • CMRR:100dB
  • Dimension of recording paper: 80mm(w)x20m(L)paper
  • Paper speed:25mm/s,50mm/s
  • Sensitivity choice:5,10,20mm/mV.Standard sensitivity is 10mm/mV+0.2mm/mV
  • Measurement parameters :HR,P-R interval , PDuration, QRS Duration,Q-T interval,Q-Tc,P Axis,QRS Axis,T Axis,R(V5), S› (V1),R(V5)+S(V1)
  • Product safety type:Class 1.Type CF, there is defibrillation and pacing protection circuit.
  • Enduring polarization voltage:+300mV
  • Noise level:=15µVp-p
  • Size:315mm(L)×215mm(W)×77mm(H)
  • Net Weight:2.25Kg
    Specifications :
  • 7" TFT, touch screen, led backlight
  • Digital isolation technology and signal processing solution, digital filter
  • Patient managment, name and age and id.
  • Detail analysis report.
  • Multi-language options: German, French, Italian, Turkish
  • Built-in lithium rechargeable battery, wide thermal printing system
  • USB and LAN socket.
  • Memory: Built-in memory or mini SD Memory card. Store more than 1000 pieces of archive
  • Auto-measurement, auto-analysis, and auto-interpretation.
  • Lead: Standard 12 leads
  • Patient leak current: <10uA
  • Input impedance: =50M
  • Frequency response:0.05 ~ 150HZ(-3dB)
  • Time constant:>3.2S
  • CMRR:>100dB
  • Dimension of recording paper: 80mmx20m
  • Paper speed: 25mm/s, 50mm/s
  • Sensitivity choice:5, 10,20mm/mV.
  • Measurement parameters:HR, P-R interval, P-Duration, QRS Duration, Q-T interval, Q-Tc,P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1)
  • Product safety type: Class I, CF. Defibrillation and pacing protection
  • Enduring polarization voltage: ±300mv
  • Noise level:<15uVp-p
  • Dimension:130mm(L)×74mm(W)×25mm(H)
  • Net weight: 2.3KG
    Specifications :
  • 12 Leads ECG simultaneous acquisition, simultaneous display of 3/6/12 leads ECG waveform
  • Build-in real-time analysis software, average QRS template,
  • RS232 and USB interface
  • Multiform printing modes and format: Auto/Manual, standard 12 Ch, 3Ch+3R, 6Ch, 6Ch+1R and 60s arrhythmia report.
  • Physical examination mode (A4 Paper) , R-R histogram, trend , average QRS template.
  • Build-in SD Card
  • Input way: Floating and defibrilation protection
  • Lead: Standard 12 leads
  • Input impedance: =50MO.
  • Frequency response: 0.05Hz~150Hz (-3dB, + 0.4dB)
  • Time constant: >3.2s
  • Noise level: =13µVp-p
  • Filter: AC filter, EMG interference filter, DFT filter
  • Sensitivity: Auto 10? 20mm/mV ±2% etc
  • Measure data: HR,interval,Duration,Axis
  • Paper speed: 25?50mm/s, ±%3 etc
  • Recording paper: 210/216mm(W)×20/30m(L)
  • Safety Type: Class I,Type CF
  • Size: 338mm(L) x 280mm(W) x 85mm(H)
  • Net Weight: 3.5Kg
  • Options:
  • ECG Workstation Software
  • SD Card
  • Portable Pack
  • Trolley
  • 7"LCD B/W, Color, Touch

Patient Monitor- Manufacturer and Exporters of Patient Monitor, Multi-parameter Monitors, Central Monitor System, Vital Signs Monitor, Handheld ECG Monitor, ECG, Spo2, NIBP, PR Monitors, Suppliers India. Trust NET brand for Surgical Instruments, Medical Supplies, Hospital Equipments, Laboratory Products & Goods.

Like Narang Medical Ltd. on Facebook
Follow Narang Medical Ltd. on Twitter
Product Videos of Narang Medical Ltd
Bookmark and Share

Meet us at:
  • FIME 2012
  • on 08th to 10th Aug. 2012
  • at Miami Beach Convention Center,
  • Miami Beach, Florida, USA.
  • Booth No. 801
Fix Appointment
  • WEST AFRICAN HEALTH 2012
  • on 05th to 07th Sep. 2012
  • at New Convention Centre, Eko Hotel & Suite
  • Victoria Island, Lagos, Nigeria.
Fix Appointment
  • PHARMED & HEALTHCARE VIETNAM 2012
  • on 26th to 29th Sept. 2012
  • at SECC, HoChiMinh City
  • Vietnam.
Fix Appointment
  • MEDICA 2012
  • on 14th to 17th Nov. 2012
  • at Dusseldorf
  • German
Fix Appointment


View All Exhibitions         

Patient Monitors

Multi-parameter Monitors

Central Monitor System

Vital Signs Monitor