All day’s accurate working of infusion pump

  • Secure : Automatic Infusion pump at constant temperature
  • Perfect: Working mode at night
  • Convenient: Weight mode conversion

  • Function:
  • Specify syringe size automatically
  • Identify syringe size automatically
  • 3-level occlusion alarm limits setting
  • Automatically reduce impact dose release after occlusion
  • Limits setting
  • Delivered volume inquiry
  • KVO flow rate
  • Fast rate control
  • “Purge” button activate safe protection
  • Flow rate setting button lock
  • Abundant optic and sound alarm
  • AC and internal power indication
  • Standard RS232 interface
  • 500 history records
SPECIFICATION (Single Channel)
Syringes 10, 20, 30, 50 ml of calibrated syringes
Flow rate 0.1-1500 ml/h (0.1 ml/h step) 50 ml syringe
0.1-900 ml/h (0.1 ml/h step) 30 ml syringe
0.1-600 ml/h (0.1 ml/h step) 20 ml syringe
0.1-400 ml/h (0.1 ml/h step) 10 ml syringe
Purge rate 1500 ml/h 50 ml syringe
900 ml/h 30 ml syringe
600 ml/h 20 ml syringe
400 ml/h 10 ml syringe
Accuracy of flow rate
(Nominal value)
Accuracy including syringe: within ±2%
Mechanical accuracy: within ±1%
Display range of volume delivered 0.1–9999 ml
(0.1–999.9 ml,0.1ml step)
(1000–9999 ml,1ml step)
Setting of delivery limit 0.1–9999 ml
(0.1–999.9 ml,0.1ml step)
(1000–9999 ml,1ml step)
Occlusion detection pressure 'H': 800±200 mmHg (106.7±26.7 kPa) or 1.09±0.27 kgf/cm²
'C': 500±100 mmHg (66.7±13.3 kPa) or 0.68±0.13 kgf/cm²
'L': 300±100 mmHg (40.7±13.3 kPa) or 0.41±0.13 kgf/cm²
Power
AC110~220V ±10%, 50~60 Hz ±1 Hz
Inner NiMH battery: DC12 V
Operation conditions Ambient temperature: 5 to 40, Relative humidity: 20% to 80%
Storage conditionsAmbient temperature: -40 to 55, Relative humidity: ≤ 95%
Electric shock protection/class Class I and internal power supply: Type CF, Continuous operation
Water proof level IPX4
Weight 2.25kg (with clamp base)
Dimension 306mm (Width)×135mm (Height)×127mm (Depth)

    International standard syringe pump

  • Compatible: Automatic syringe calibration, suitable for all brands
  • Convenient: “Openable slider hook”, convenient to clamp syringe plunger
  • Powerful: Battery capable to support more than 6 hours for one channel continuous working
  • Energy saving: Idle channel can be set to sleeping mode

  • Function:
  • Body weight mode input
  • Specify syringe size automatically
  • Identify syringe size automatically
  • 3-level occlusion alarm limits setting
  • Automatically reduce impact dose release after occlusion
  • Limits setting
  • Delivered volume inquiry
  • KVO flow rate
  • Fast rate control
  • “Purge” button activate safe protection
  • Flow rate setting button lock
  • Abundant optic and sound alarm
  • AC and internal power indication
  • Standard RS232 interface
  • 500 history records
SPECIFICATION (Single Channel, Body Weight Mode)
Syringes 10, 20, 30, 50 ml of calibrated syringes
Flow rate 0.1-1500 ml/h (0.1 ml/h step) 50 ml syringe
0.1-900 ml/h (0.1 ml/h step) 30 ml syringe
0.1-600 ml/h (0.1 ml/h step) 20 ml syringe
0.1-400 ml/h (0.1 ml/h step) 10 ml syringe
Purge rate 1500 ml/h 50 ml syringe
900 ml/h 30 ml syringe
600 ml/h 20 ml syringe
400 ml/h 10 ml syringe
Accuracy of flow rate
(Nominal value)
Accuracy including syringe: within ±2%
Mechanical accuracy: within ±1%
Display range of volume delivered 0.1–9999 ml
(0.1–999.9 ml,0.1ml step)
(1000–9999 ml,1ml step)
Setting of delivery limit 0.1–9999 ml
(0.1–999.9 ml,0.1ml step)
(1000–9999 ml,1ml step)
Occlusion detection pressure 'H': 800±200 mmHg (106.7±26.7 kPa) or 1.09±0.27 kgf/cm²
'C': 500±100 mmHg (66.7±13.3 kPa) or 0.68±0.13 kgf/cm²
'L': 300±100 mmHg (40.7±13.3 kPa) or 0.41±0.13 kgf/cm²
Power
AC110~220V ±10%, 50~60 Hz ±1 Hz
Inner NiMH battery: DC12 V
Operation conditions Ambient temperature: 5 to 40, Relative humidity: 20% to 80%
Storage conditionsAmbient temperature: -40 to 55, Relative humidity: ≤ 95%
Electric shock protection/class Class I and internal power supply: Type CF, Continuous operation
Water proof level IPX4
Weight 2.25kg (with clamp base)
Dimension 306mm (Width)×135mm (Height)×127mm (Depth)

    International standard syringe pump

  • Compatible: Automatic syringe calibration, suitable for all brands
  • Convenient: “Openable slider hook”, convenient to clamp syringe plunger
  • Powerful: Battery capable to support more than 6 hours for one channel continuous working
  • Energy saving: Idle channel can be set to sleeping mode

  • Function:
  • Dual-channel with different flow rate
  • Channel sleeping function
  • 3-level occlusion alarm limits setting
  • Limits setting
  • Automatically reduce impact dose release after occlusion
  • Delivered volume inquiry
  • KVO flow rate
  • Fast rate control
  • “Purge” button activate safe protection
  • Flow rate setting button lock
  • Abundant optic and sound alarm
  • AC and internal power indication
  • Standard RS232 interface
  • 500 history records
SPECIFICATION (Dual Channel)
Syringes 10, 20, 30, 50 ml of calibrated syringes
Flow rate 0.1-1500 ml/h (0.1 ml/h step) 50 ml syringe
0.1-900 ml/h (0.1 ml/h step) 30 ml syringe
0.1-600 ml/h (0.1 ml/h step) 20 ml syringe
0.1-400 ml/h (0.1 ml/h step) 10 ml syringe
Purge rate 1500 ml/h 50 ml syringe
900 ml/h 30 ml syringe
600 ml/h 20 ml syringe
400 ml/h 10 ml syringe
Accuracy of flow rate
(Nominal value)
Accuracy including syringe: within ±2%
Mechanical accuracy: within ±1%
Display range of volume delivered 0.1–9999 ml
(0.1–999.9 ml,0.1ml step)
(1000–9999 ml,1ml step)
Setting of delivery limit 0.1–9999 ml
(0.1–999.9 ml,0.1ml step)
(1000–9999 ml,1ml step)
Occlusion detection pressure 'H': 800±200 mmHg (106.7±26.7 kPa) or 1.09±0.27 kgf/cm²
'C': 500±100 mmHg (66.7±13.3 kPa) or 0.68±0.13 kgf/cm²
'L': 300±100 mmHg (40.7±13.3 kPa) or 0.41±0.13 kgf/cm²
Power
AC110~220V ±10%, 50~60 Hz ±1 Hz
Inner NiMH battery: DC12 V
Operation conditions Ambient temperature: 5 to 40, Relative humidity: 20% to 80%
Storage conditionsAmbient temperature: -40 to 55, Relative humidity: ≤ 95%
Electric shock protection/class Class I and internal power supply: Type CF, Continuous operation
Water proof level IPX4
Weight 3.45kg (with clamp base)
Dimension 354mm (Width)×190mm (Height)×128mm (Depth)

They have been A+ in quality, pricing and after sales service...



Quick Response :


Meet us at:
  • Arab Health 2017
  • 30th Jan. to 02nd Feb., 2017
  • at Dubai International Convention
  • & Exhibition Centre,
  • Dubai, U.A.E.
  • Booth No.: CC25
Fix Appointment
  • Medical Fair India 2017
  • 06th to 08th April, 2017
  • at Pragati Maidan,
  • New Delhi, India.
Fix Appointment
  • FIME 2017
  • 8th to 10th August, 2017
  • at Orange County Convention Center,
  • West Concourse, Orlando,
  • Florida, USA.
Fix Appointment
  • MEDICA 2017
  • 13th to 16th November, 2017
  • in Dusseldorf, Germany.
Fix Appointment


View All Exhibitions         

Exhibitions     |     Send Query
Orthopaedic Implants

Syringe Pump

Syringe Pump Manufacturers

Syringe Pump Suppliers

Syringe Pump Manufacturer India