Function:
  • Identify/Specify syringe size automatically
  • 3-level occlusion alarm limits setting
  • Automatically reduce impact dose release after occlusion
  • Delivered volume inquiry
  • KVO flow rate / Fast rate control
  • “Purge” button activate safe protection
  • Flow rate setting button lock / Limits setting
  • Abundant optic and sound alarm
  • AC and internal power indication
  • Standard RS232 interface
  • 500 history records
SPECIFICATION (Single Channel)
Syringes 10, 20, 30, 50 ml of calibrated syringes
Flow rate 0.1-1500 ml/h (0.1 ml/h step) 50 ml syringe
0.1-900 ml/h (0.1 ml/h step) 30 ml syringe
0.1-600 ml/h (0.1 ml/h step) 20 ml syringe
0.1-400 ml/h (0.1 ml/h step) 10 ml syringe
Accuracy of flow rate Accuracy including syringe: within ±2%
    Function:
  • Body weight mode input
  • Identify/Specify syringe size automatically
  • 3-level occlusion alarm limits setting
  • Automatically reduce impact dose release after occlusion
  • Delivered volume inquiry
  • KVO flow rate / Fast rate control
  • “Purge” button activate safe protection
  • Flow rate setting button lock / Limits setting
  • Abundant optic and sound alarm
  • AC and internal power indication
  • Standard RS232 interface
  • 500 history records
SPECIFICATION (Single Channel, Body Weight Mode)
Syringes 10, 20, 30, 50 ml of calibrated syringes
Flow rate 0.1-1500 ml/h (0.1 ml/h step) 50 ml syringe
0.1-900 ml/h (0.1 ml/h step) 30 ml syringe
0.1-600 ml/h (0.1 ml/h step) 20 ml syringe
0.1-400 ml/h (0.1 ml/h step) 10 ml syringe
Accuracy of flow rate Accuracy including syringe: within ±2%
    Function:
  • Dual-channel with different flow rate
  • Channel sleeping function
  • 3-level occlusion alarm limits setting
  • Automatically reduce impact dose release after occlusion
  • Delivered volume inquiry
  • KVO flow rate / Fast rate control
  • “Purge” button activate safe protection
  • Flow rate setting button lock / Limits setting
  • Abundant optic and sound alarm
  • AC and internal power indication
  • Standard RS232 interface
  • 500 history records
SPECIFICATION (Dual Channel)
Syringes 10, 20, 30, 50 ml of calibrated syringes
Flow rate 0.1-1500 ml/h (0.1 ml/h step) 50 ml syringe
0.1-900 ml/h (0.1 ml/h step) 30 ml syringe
0.1-600 ml/h (0.1 ml/h step) 20 ml syringe
0.1-400 ml/h (0.1 ml/h step) 10 ml syringe
Accuracy of flow rate Accuracy including syringe: within ±2%

They have been A+ in quality, pricing and after sales service...



Quick Response :


Meet us at:
  • PHA Exhibition 2017
  • 15th to 17th Nov., 2017
  • at Manila Hotel, Manila, Philippines.
  • Booth No.: 23, 24, 25, 26
Fix Appointment
  • Arab Health 2018
  • 29th Jan to 01st Feb, 2018
  • at Dubai International Convention and Exhibition Centre, Dubai, U.A.E.
Fix Appointment
  • AAOS 2018
  • 6th to 10th March, 2018
  • at New Orleans, Louisiana, USA.
Fix Appointment
  • Africa Health 2018
  • 29th to 31st May, 2018
  • at Gallagher Convention Centre, Midrand, Johannesburg, South Africa.
Fix Appointment


View All Exhibitions         

Exhibitions     |     Send Query
Orthopaedic Implants

Syringe Pump

Syringe Pump Manufacturers

Syringe Pump Suppliers

Syringe Pump Manufacturer India