    These are mobile Warmer mounted on wheels with fixed baby cradle, lower shelf and 3 drawers storage Cabinet.

    Technical Specification
    Heater Box

  • Consists of Ceramic Infra Red Heater 650 Watts
  • The source box can be swivelled to take X-ray.
  • Due to temp. insulated cover on the heater box, its exterior surface remains cool even after long run.
  • The construction of the stainless steel reflector and Guard rail is such that the complete cleaning of heater & reflector is possible without any electrical shock hazards.
  • Halogen Examination Lamp (12 Volts, 50 Watts)
    To provide accurate assessment of Infant colour and sufficient illumination during procedures.

    Baby Tray (Stainless Steel)
  • Clear acrylic collapsible side panels .
  • Stainless steel baby tray with transparent slot to incorporate the facility of under surface phototherapy.
  • Acrylic tray and cushion mattress with head up/down facility.
  • Acrylic X-ray tray with X-ray guide for positioning the cassette.
  • The design aspects also allow ease of dismantling baby care area during cleaning or fumigation.
  • Essential Attachments
  • Lower Shelf and 3 Drawer Storage Cabinet.
  • Side Mounted Monitor tray.
  • Pole for Syringe Pump / Infusion Pump.
  • S.S. IV Stand.
  • For Skin / Manual mode, following are the feature:

    Control Modes: Skin / Manual.
    Range: Skin control: 34 to 38 ˚C
    Resolution: 0.1˚ C
    Accuracy: ± 0.2˚ C
    Display: 1” bright skin & air temp.(7 segment LED)
                    % of heater output (bar graph)"
    Status: On LED
    Timer: Timer / APGAR
    Manual mode: Time Programmable
                               Heater output settable
                               Over temp. cut-off
    Alarm: Auto audio alarm mute, Mute time programmable
    Safety alarms: ON LED

    The mentioned are default limit, can be set or alter as per requirement:
  • Skin High 0.5˚C.
  • Skin Low 0.5˚C.
  • Under range (<34˚C).
  • Over range (>38˚C)e.
  • Heater Failure.
  • Power control failure.
  • Probe and power failure alarm.
    These are mobile Warmer mounted on wheels with fixed baby cradle, lower shelf and 3 drawers storage Cabinet.

    Technical Specification
    Heater Box

  • Consists of Ceramic Infra Red Heater 650 Watts
  • The source box can be swivelled to take X-ray.
  • Due to temp. insulated cover on the heater box, its exterior surface remains cool even after long run.
  • The construction of the stainless steel reflector and Guard rail is such that the complete cleaning of heater & reflector is possible without any electrical shock hazards.
  • Halogen Examination Lamp (12 Volts, 50 Watts)
    To provide accurate assessment of Infant colour and sufficient illumination during procedures.

    Baby Tray (Stainless Steel)
  • Clear acrylic collapsible side panels .
  • Stainless steel baby tray with transparent slot to incorporate the facility of under surface phototherapy.
  • Acrylic tray and cushion mattress with head up/down facility.
  • Acrylic X-ray tray with X-ray guide for positioning the cassette.
  • The design aspects also allow ease of dismantling baby care area during cleaning or fumigation.
  • Essential Attachments
  • Lower Shelf and 3 Drawer Storage Cabinet.
  • Side Mounted Monitor tray.
  • Pole for Syringe Pump / Infusion Pump.
  • S.S. IV Stand.
  • For Skin / Air / Manual mode, following are the feature:

    Control Modes: Skin / Air / Manual.
    Range:Skin control: 34 to 38 ˚C
    Air control: Room temp. to 39˚ C"
    Resolution: 0.1˚ C
    Accuracy: ± 0.2˚ C
    Display: 1” bright skin & air temp.(7 segment LED)
                    % of heater output (bar graph)"
    Status: On LED
    Timer: Timer / APGAR Timer/Baby Attend
    Manual mode: Time Programmable
                               Heater output settable
                               Over temp. cut-off
    Alarm: Auto audio alarm mute, Mute time programmable
    Safety alarms: ON LED

    The mentioned are default limit, can be set or alter as per requirement:
  • Skin Mode.
  •     - Skin High 0.5˚C
        - Skin Low 0.5˚C
        - Under range(<34˚C)
        - Over range(>38˚C)
  • Air Mode.
  •     - Air high 1.5˚C
        - Low 3.0˚C
        - Over range
  • Heater Failure.
  • Power Control Failure.
  • Probe & Power failure alarm.
    This is mobile Warmer mounted on wheels with fixed baby cradle.

    Mechanical Specification
    Heater Box

  • Consists of Ceramic Infra Red Heater 650 Watts
  • The source box can be swivelled to take X-ray.
  • Due to temp. insulated cover on the heater box, its exterior surface remains cool even after long run.
  • The construction of the stainless steel reflector and Guard rail is such that the complete cleaning of heater & reflector is possible without any electrical shock hazards.
  • Halogen Examination Lamp (12 Volts, 50 Watts)
    To provide accurate assessment of Infant colour and sufficient illumination during procedures.

    Baby Tray (Stainless Steel)
  • Clear acrylic collapsible side panels .
  • Stainless steel baby tray with transparent slot to incorporate the facility of under surface phototherapy.
  • Acrylic tray and cushion mattress with head up/down facility.
  • Acrylic X-ray tray with X-ray guide for positioning the cassette.
  • The design aspects also allow ease of dismantling baby care area during cleaning or fumigation.
  • Essential Attachments
  • 2 Lower Shelves.
  • Side Mounted Monitor tray, Pole for Syringe Pump / Infusion Pump & S.S. IV Stand.
  • For Skin / Air / Manual mode, following are the feature:

    Control Modes: Skin / Manual.
    Range: Skin control: 34 to 38 ˚C
    Resolution: 0.1˚ C
    Accuracy: ± 0.2˚ C
    Display: 1” bright skin & air temp.(7 segment LED)
                    % of heater output (bar graph)"
    Status: On LED
    Timer: Timer / APGAR
    Manual mode: Time Programmable
                               Heater output settable
                               Over temp. cut-off
    Alarm: Auto audio alarm mute, Mute time programmable
    Safety alarms: ON LED

    The mentioned are default limit, can be set or alter as per requirement:
  • Skin High 0.5˚C.
  • Skin Low 0.5˚C.
  • Under range (<34˚C).
  • Over range (>38˚C)e.
  • Heater Failure.
  • Power control failure.
  • Probe and power failure alarm.
    This is mobile Warmer mounted on wheels with fixed baby cradle.

    Mechanical Specification
    Heater Box

  • Consists of Ceramic Infra Red Heater 650 Watts
  • The source box can be swivelled to take X-ray.
  • Due to temp. insulated cover on the heater box, its exterior surface remains cool even after long run.
  • The construction of the stainless steel reflector and Guard rail is such that the complete cleaning of heater & reflector is possible without any electrical shock hazards.
  • Halogen Examination Lamp (12 Volts, 50 Watts)
    To provide accurate assessment of Infant colour and sufficient illumination during procedures.

    Baby Tray (Stainless Steel)
  • Clear acrylic collapsible side panels .
  • Stainless steel baby tray with transparent slot to incorporate the facility of under surface phototherapy.
  • Acrylic tray and cushion mattress with head up/down facility.
  • Acrylic X-ray tray with X-ray guide for positioning the cassette.
  • The design aspects also allow ease of dismantling baby care area during cleaning or fumigation.
  • Essential Attachments
  • 2 Lower Shelves.
  • Side Mounted Monitor tray, Pole for Syringe Pump / Infusion Pump & S.S. IV Stand.
  • For Skin / Air / Manual mode, following are the feature:

    Control Modes: Skin / Air / Manual.
    Range:Skin control: 34 to 38 ˚C
    Air control: Room temp. to 39˚ C"
    Resolution: 0.1˚ C
    Accuracy: ± 0.2˚ C
    Display: 1” bright skin & air temp.(7 segment LED)
                    % of heater output (bar graph)"
    Status: On LED
    Timer: Timer / APGAR Timer/Baby Attend
    Manual mode: Time Programmable
                               Heater output settable
                               Over temp. cut-off
    Alarm: Auto audio alarm mute, Mute time programmable
    Safety alarms: ON LED

    The mentioned are default limit, can be set or alter as per requirement:
  • Skin Mode.
  •     - Skin High 0.5˚C
        - Skin Low 0.5˚C
        - Under range (<34˚C)
        - Over range (>38˚C)
  • Air Mode.
  •     - Air high 1.5˚C
        - Low 3.0˚C
        - Over range
  • Heater Failure.
  • Power Control Failure.
  • Probe & Power failure alarm.
    This is mobile Warmer mounted on wheels with fixed baby cradle.

    Mechanical Specification
    Heater Box

  • Consists of Ceramic Infra Red Heater 650 Watts
  • The source box can be swivelled to take X-ray.
  • Due to temp. insulated cover on the heater box, its exterior surface remains cool even after long run.
  • The construction of the stainless steel reflector and Guard rail is such that the complete cleaning of heater & reflector is possible without any electrical shock hazards.
  • Technical Specification
    Heater Box

  • Consists of Ceramic Infra Red Heater 650 Watts
  • The source box can be swivelled to take X-ray.
  • Due to temp. insulated cover on the heater box, its exterior surface remains cool even after long run.
  • The construction of the stainless steel reflector and Guard rail is such that the complete cleaning of heater & reflector is possible without any electrical shock hazards.
  • Halogen Examination Lamp (12 Volts, 50 Watts)
    To provide accurate assessment of Infant colour and sufficient illumination during procedures.

    Essential Attachments
  • Side Mounted Monitor tray, Pole for Syringe Pump / Infusion Pump.
  • S.S. IV Stand.
  • For Skin / Manual mode, following are the feature:

    Control Modes: Skin / Manual.
    Range: Skin control: 34 to 38 ˚C
    Resolution: 0.1˚ C
    Accuracy: ± 0.2˚ C
    Display: 1” bright skin & air temp.(7 segment LED)
                    % of heater output (bar graph)"
    Status: On LED
    Timer: Timer / APGAR
    Manual mode: Time Programmable
                               Heater output settable
                               Over temp. cut-off
    Alarm: Auto audio alarm mute, Mute time programmable
    Safety alarms: ON LED

    The mentioned are default limit, can be set or alter as per requirement:
  • Skin High 0.5˚C.
  • Skin Low 0.5˚C.
  • Under range (<34˚C).
  • Over range (>38˚C)e.
  • Heater Failure.
  • Power control failure.
  • Probe and power failure alarm.
    This is mobile Warmer mounted on wheels with fixed baby cradle.

    Mechanical Specification
    Heater Box

  • Consists of Ceramic Infra Red Heater 650 Watts
  • The source box can be swivelled to take X-ray.
  • Due to temp. insulated cover on the heater box, its exterior surface remains cool even after long run.
  • The construction of the stainless steel reflector and Guard rail is such that the complete cleaning of heater & reflector is possible without any electrical shock hazards.
  • Technical Specification
    Heater Box

  • Consists of Ceramic Infra Red Heater 650 Watts
  • The source box can be swivelled to take X-ray.
  • Due to temp. insulated cover on the heater box, its exterior surface remains cool even after long run.
  • The construction of the stainless steel reflector and Guard rail is such that the complete cleaning of heater & reflector is possible without any electrical shock hazards.
  • Halogen Examination Lamp (12 Volts, 50 Watts)
    To provide accurate assessment of Infant colour and sufficient illumination during procedures.

    Essential Attachments
  • Side Mounted Monitor tray, Pole for Syringe Pump / Infusion Pump.
  • S.S. IV Stand.
  • For Skin / Air / Manual mode, following are the feature:

    Control Modes: Skin / Air / Manual.
    Range: Skin control: 34 to 38 ˚C
    Air control: Room temp. to 39˚ C"
    Resolution: 0.1˚ C
    Accuracy: ± 0.2˚ C
    Display: 1” bright skin & air temp.(7 segment LED)
                    % of heater output (bar graph)"
    Status: On LED
    Timer: Timer / APGAR Timer/Baby Attend
    Manual mode: Time Programmable
                               Heater output settable
                               Over temp. cut-off
    Alarm: Auto audio alarm mute, Mute time programmable
    Safety alarms: ON LED

    The mentioned are default limit, can be set or alter as per requirement:
  • Skin Mode.
  •     - Skin High 0.5˚C
        - Skin Low 0.5˚C
        - Under range (<34˚C)
        - Over range (>38˚C)
  • Air Mode.
  •     - Air high 1.5˚C
        - Low 3.0˚C
        - Over range
  • Heater Failure.
  • Power Control Failure.
  • Probe & Power failure alarm.
    This is mobile Warmer mounted on wheels with fixed baby cradle.

    Mechanical Specification
    Heater Box

  • Consists of Ceramic Infra Red Heater 650 Watts
  • The source box can be swivelled to take X-ray.
  • Due to temp. insulated cover on the heater box, its exterior surface remains cool even after long run.
  • The construction of the stainless steel reflector and Guard rail is such that the complete cleaning of heater & reflector is possible without any electrical shock hazards.
  • Technical Specification
    Heater Box

  • Consists of Ceramic Infra Red Heater 650 Watts
  • The source box can be swivelled to take X-ray.
  • Due to temp. insulated cover on the heater box, its exterior surface remains cool even after long run.
  • The construction of the stainless steel reflector and Guard rail is such that the complete cleaning of heater & reflector is possible without any electrical shock hazards.
  • Halogen Examination Lamp (12 Volts, 50 Watts)
    To provide accurate assessment of Infant colour and sufficient illumination during procedures.

    Essential Attachments
  • Side Mounted Monitor tray, Pole for Syringe Pump / Infusion Pump.
  • S.S. IV Stand.
  • Infant Care Trolley Premium
  • Clear acrylic collapsible side panels to assess an infant from all sides.
  • Stainless steel baby tray with transparent slot to incorporate the facility of under surface phototherapy.
  • Acrylic tray and cushion mattress with head up/down facility.
  • Acrylic X-ray tray with X-ray guide for positioning the cassette.
  • Two Lower shelves.
  • Mounted on wheel 4".
  • The design aspects also allow easy of dismantling baby care area during cleaning or fumigation.
  • For Skin / Manual mode, following are the feature:

    Control Modes: Skin / Manual.
    Range: Skin control: 34 to 38 ˚C
    Resolution: 0.1˚ C
    Accuracy: ± 0.2˚ C
    Display: 1” bright skin & air temp.(7 segment LED)
                    % of heater output (bar graph)"
    Status: On LED
    Timer: Timer / APGAR
    Manual mode: Time Programmable
                               Heater output settable
                               Over temp. cut-off
    Alarm: Auto audio alarm mute, Mute time programmable
    Safety alarms: ON LED

    The mentioned are default limit, can be set or alter as per requirement:
  • Skin High 0.5˚C.
  • Skin Low 0.5˚C.
  • Under range (<34˚C).
  • Over range (>38˚C)e.
  • Heater Failure.
  • Power control failure.
  • Probe and power failure alarm.
    This is mobile Warmer mounted on wheels with fixed baby cradle.

    Mechanical Specification
    Heater Box

  • Consists of Ceramic Infra Red Heater 650 Watts
  • The source box can be swivelled to take X-ray.
  • Due to temp. insulated cover on the heater box, its exterior surface remains cool even after long run.
  • The construction of the stainless steel reflector and Guard rail is such that the complete cleaning of heater & reflector is possible without any electrical shock hazards.
  • Technical Specification
    Heater Box

  • Consists of Ceramic Infra Red Heater 650 Watts
  • The source box can be swivelled to take X-ray.
  • Due to temp. insulated cover on the heater box, its exterior surface remains cool even after long run.
  • The construction of the stainless steel reflector and Guard rail is such that the complete cleaning of heater & reflector is possible without any electrical shock hazards.
  • Halogen Examination Lamp (12 Volts, 50 Watts)
    To provide accurate assessment of Infant colour and sufficient illumination during procedures.

    Essential Attachments
  • Side Mounted Monitor tray, Pole for Syringe Pump / Infusion Pump.
  • S.S. IV Stand.
  • Infant Care Trolley Premium
  • Clear acrylic collapsible side panels to assess an infant from all sides.
  • Stainless steel baby tray with transparent slot to incorporate the facility of under surface phototherapy.
  • Acrylic tray and cushion mattress with head up/down facility.
  • Acrylic X-ray tray with X-ray guide for positioning the cassette.
  • Two Lower shelves.
  • Mounted on wheel 4".
  • The design aspects also allow easy of dismantling baby care area during cleaning or fumigation.
  • For Skin / Manual mode, following are the feature:

    Control Modes: Skin / Manual.
    Range: Skin control: 34 to 38 ˚C
    Air control: Room temp. to 39˚ C".
    Resolution: 0.1˚ C
    Accuracy: ± 0.2˚ C
    Display: 1” bright skin & air temp.(7 segment LED)
                    % of heater output (bar graph)"
    Status: On LED
    Timer: Timer / APGAR Timer/Baby Attend
    Manual mode: Time Programmable
                               Heater output settable
                               Over temp. cut-off
    Alarm: Auto audio alarm mute, Mute time programmable
    Safety alarms: ON LED

    The mentioned are default limit, can be set or alter as per requirement:
  • Skin Mode.
  •     - Skin High 0.5˚C
        - Skin Low 0.5˚C
        - Under range (<34˚C)
        - Over range (>38˚C)
  • Air Mode.
  •     - Air high 1.5˚C
        - Low 3.0˚C
        - Over range
  • Heater Failure.
  • Power Control Failure.
  • Probe & Power failure alarm.

Trolly: 1   2



Infant Radiant Warmer / Open Care System- Manufacture exporters of Infant Radiant Warmer / Open Care System. Trust NET brand for Surgical Instruments, Medical Supplies, Hospital Equipments, Laboratory Products & Goods.

Like Narang Medical Ltd. on Facebook
Follow Narang Medical Ltd. on Twitter
Product Videos of Narang Medical Ltd
Bookmark and Share

Meet us at:
  • FIME 2012
  • on 08th to 10th Aug. 2012
  • at Miami Beach Convention Center,
  • Miami Beach, Florida, USA.
  • Booth No. 801
Fix Appointment
  • WEST AFRICAN HEALTH 2012
  • on 05th to 07th Sep. 2012
  • at New Convention Centre, Eko Hotel & Suite
  • Victoria Island, Lagos, Nigeria.
Fix Appointment
  • PHARMED & HEALTHCARE VIETNAM 2012
  • on 26th to 29th Sept. 2012
  • at SECC, HoChiMinh City
  • Vietnam.
Fix Appointment
  • MEDICA 2012
  • on 14th to 17th Nov. 2012
  • at Dusseldorf
  • German
Fix Appointment


View All Exhibitions         

Infant Radiant Warmer

Open Care System

Neonatal Open Care System

Manufacturer