Specifications : | ||
---|---|---|
Power Supply | AC 110V / 220V 60/50 Hz | |
Power Input | 120VA | |
Wavelength (blue light) | 400nm ~ 550nm | |
Total Irradiance for bilirubin | 1300 µ W/cm2 | |
Height Adjust Range | 1300 ~ 1600mm | |
Pitching angle of phototherapy head | ± 90° | |
Time Accuracy | 1min/12h | |
Integral time range | 0h ~ 9999h 59min | |
Operating Condition | Temperature | 18ºC ~ 30ºC |
Relative Humidity | 10% ~ 85% RH | |
Atmospheric pressure | 700hpa ~ 1060hpa | |
Transport and Storage | Ambient temperature | -10ºC ~ +55ºC |
Relative humidity | ≤95% | |
Atmospheric pressure | 500hpa ~ 1060hpa |
Specifications : | ||
---|---|---|
Power Supply | AC 110V ~ 240V 60/50 Hz | |
Power Input | 40VA | |
Wavelength Radiation | 420nm ~ 490nm | |
Height Adjust Range | 850 ~ 1640nm | |
Angle of phototherapy head | 0-180º | |
Head size | 380 x 220 mm | |
Life span of LED bulb | At least 20000 hours | |
Blue LED bulb | 17 pcs | |
Time Accuracy | 1min/12h | |
Integral time range | 0h ~ 9999.9h | |
Count down timer | 0 ~ 8h 30min | |
Total Irradiation for bilirubin (effective surface area 500 x 360mm, at 360mm) |
high | 2800 µ W/cm2 |
middle | 2000 µ W/cm2 | |
low | 800 µ W/cm2 | |
Operating Condition | Temperature | 18ºC ~ 30ºC |
Relative humidity | 10% ~ 85% RH | |
Atmospheric pressure | 700hpa ~ 1060hpa | |
Transport and Storage | Ambient temperature | -10ºC ~ +55ºC |
Relative humidity | ≤95% | |
Atmospheric pressure | 500hpa ~ 1060hpa |
Technical Data : | |
---|---|
Power Supply | AC220V±10%, 50Hz±2% |
Power Input | ≤400VA |
Blue light wavelength | 420nm ~ 490nm |
Circle 360 light radiation | 3700μW/cm2 |
Up side light radiation | 3300μW/cm2 |
Down side light radiation | 2400μW/cm2 |
Life span of blue light tube | >20000hours |
Air temperature display range | 0~45 0°C |
Skin temperature display range | 0~45 0°C |
Time accuracy | 1min/2h |
Count-up time range | 0~99.9 hours |
Count-down time range | 1min~99.9hours |
Total cumulative time | 999999hours |
Mattress size | 613x300mm |
Four alarm functions | Power failure, probe failure,over temperature, fan failure |
Working environment : | |
---|---|
Ambient temperature | +18°C~+30°C |
Relative humidity | 30%~75% |
Atmospheric pressure | 700hpa~1060hpa |
Transport and Storage : | |
---|---|
Environment Temperature | -40°C~ +55°C |
Environment Relative Humidity | ≤95% |
Atmospheric Pressure | 500~1060hPa |
Package : | |
---|---|
Each unit is packed one case Size | 140cm x 84cm x 90cm |
Gross weight | <80KG |
Categories
What our Clients are Saying
The organic reviews not hoax.
Meet Us At
Booth No.: A01
13th to 15th Jun. 2024
IICC Dwarka, New Delhi, India
Booth No.: F11
19th to 21st Jun. 2024
Miami Beach Convention Center, Miami Beach, Florida, USA
Booth No.: 504C Hall 11-16
9th to 12th Jul. 2024
Bogotá, Colombia
Let's profit together!
We are looking for distributors in your area.