Product Details:
Special Features:
Technical Features : | |||||
---|---|---|---|---|---|
Material | Mild Steel | ||||
Usage/Application | Separating Red Blood Cells And White Blood Cells | ||||
Model Name/Number | HBT1050E | ||||
Capacity | 800 ml | ||||
Temperature Range | 10 - 35 Degree C | ||||
Weight | 3 Kg | ||||
Plate Type | Transparent Acrylic Plate | ||||
Machine Type | Manual | ||||
Size | 165 x 225 x 265 mm |
Technical Features : | |||||
---|---|---|---|---|---|
Code | LD1200 | LD1201 | LD1202 | LD1203 | LD1204 |
Capacity | 150L | 200L | 250L | 300L | 400L |
Temp. Range | 0~65°C | ||||
Temp. Fluctuation | ±1°C | ||||
Temp. Uniformity | ±2°C | ||||
Shelves | 2 pcs/ adjustable | ||||
Time Range | 0~99h59min | ||||
Refrigerant | R134a (CFC free,eco-friendly) | ||||
Standard Accessory | BOD socket; built-in printer | ||||
Consumption | 300W | 350W | 450W | 500W | 400W |
Power Supply | 110/220V±10%, 50/60Hz | ||||
Packing Size(mm) | 730*780*1600 | 750*800*1750 | 780*840*1820 | 820*850*1920 | 880*900*2020 |
Gross Weight(kg) | 120 | 138 | 147 | 157 | 170 |
Technical Features : | |||
---|---|---|---|
Code | LD1205 | LD1206 | LD1207 |
Capacity | 80L | 160L | 270L |
Heating | Air jacket/water jacket | ||
Temp. Range | RT +5 ~ 60°C | ||
Control Type | PID control | ||
Temp. Fluctuation | < ±0.2°C | ||
Temp. Uniformity | < ±0.3°C | ||
Time Setting | 999h or continuous | ||
Alarm | Over-temperature alarm, CO2 Concentration alarm; Temperature sensor error alarm; Water-shortage alarm. | ||
Material | External cold-rolled steel with painting Internal stainless steel | ||
Door | Double | ||
Insulation Material | Polystyrene film | ||
CO2 Control | Infrared sensor, Range 0~20% | ||
Humidification Type | Water tank for natural evaporation | ||
Sterilization Type | UV lamp | ||
Power Supply | AC220V±10%, 50/60Hz | ||
Consumption | 600w(air jacket) 900w(water jacket) |
700w(air jacket) 1200w(water jacket) |
1200w(air jacket) 2100w(water jacket) |
Packing Size (mm) | 700*740*1020 | 700*740*1020 | 900*940*1260 |
Gross Weight (kg) | 90 | 115 | 165 |
Technical Features : | ||
---|---|---|
Code | LD1208 | LD1209 |
Type | Bench-top, Discrete,Fully automatic | Vertical, Discrete,Fully automatic |
Throughput | 200T/H | 400T/H |
Analysis Method | End-point, Fixed-time, Rate | End-point,kinetic,Two-point |
Sample Positions | 49 sample positions | 120 sample positions |
Reagent Positions | 56 refrigerated reagent positions | 90 pcs (With refrigerated function) |
Sample Volume | 2ul ~70ul (0.1ul stepping) | 2-30ul,0.1"l step |
Reagent Volume | R1&R2:20ul ~350ul (1ul stepping) | 20-300μl,1μl step |
Probe cleaning | Automatic washing both interior and exterior | Automatic washing both interior and exterior |
Reagent tray cooling | Continuous 2°C~8°C cooling within 24 hours | Continuous 2°C~8°C cooling within 24 hours |
Reaction Time | 10 minutes | 10 minutes |
Temperature Control | 37°C±0.1°C, with online software monitor the temperature | 37±0.1°C,automatic heating |
Cuvettes | 120 reusable reaction cuvettes (optical path length 6mm) | 90 reusable reaction cuvettes |
Mixer probe | After adding reagent and sample, blending immediately | -- |
Washing | After finishtesting, washing probe wash cuvettes automatically | After finishtesting, washing probe wash cuvettes automatically |
Light Source | 12V/30W halogen-tungsten lamp, 2000 hours | Halogen-tungsten lamp |
Spectroscopic methods | Post light split detection technique | -- |
Wavelength Range | 340,405,450,510,546,578,630,700nm | 340-700nm,8 wavelengths,(4 positions are optional) |
Linear Range | 0.000~3.000Abs | 0.0001Abs |
Power Supply | 110/220V±10% , 50/60Hz | AC110/220V,±10%, 50/60Hz,1000VA |
Package Size (W*D*H) | 1120*730*980mm | 1220*1340*890mm |
Gross Weight | 185kg | 200Kg |
Technical Features : | ||
---|---|---|
Code | LD1210 | LD1211 |
Reading cuvette | Both through cell and direct reading cuvette | Direct reading cuvette |
Incubating positions | 20 incubating positions | 20 incubating positions |
Photometric System | Light source:6V, 10W long life halogen lamp. Filters: 340/405/492/510/546/578/620nm, 2 more open filter positions, ±2nm pass-hand Wavelength accuracy:±2nm |
|
Measuring System | Measuring range: 0-2.500 O.D. Photometric linearity: ±2% from 0 to 2.000 O.D. Photometric accuracy: ±2% from 0 to 2.001 O.D. Drift<0.005 O.D. Carry over <1& | |
Incubator temperature control | 25°C, 30°C, 37°C, RT Precision: ±0.1°C | 25°C, 30°C, 37°C, RT Precision: ±0.1°C |
Display/Keyboard | Touch Screen (Membrane key optional) | Back-illuminated LCD/Membrane key |
Power Supply | AC 110V 60Hz/220V 50Hz | AC 110V 60Hz/220V 50Hz |
Dimensions | 34cm*38cm*18cm | 34cm*38cm*18cm |
Weight | 8.5Kg | 8.5Kg |
Technical Features : | |
---|---|
Code | LD1212 |
Testing channel | 1 |
Display | 4.3 inch screen |
Cuvette incubation positions | 5 |
Reagent incubation positions | 2 |
Wavelength | LED 470nm |
Sample type | Plasma |
Memory | 10000 results storage |
Sample volume | 20-40µl |
Electronic Pipette | 20-40µl |
Available dimensions | Seconds, ratio, %, g/L |
Incubation Temperature | 37.0±1.0°C |
Relative humidity | ≤85% |
Precision | PT, APTT, FIB <5%; TT <8%(Normal sample) |
Deviation between channels | <5% |
Power supply | AC100-240V, 50/60Hz |
Net weight | 2.1kg |
Dimension | 290*260*135mm |
Package size | 360*360*260mm |
Gross weight | 6.5kg |
Technical Features : | |
---|---|
Code | LD1213 |
Testing channel | 2 |
Display | 4.3 inch screen |
Cuvette incubation positions | 12 |
Reagent incubation positions | 5 |
Wavelength | LED 470nm |
Sample type | Plasma |
Memory | 10000 results storage |
Sample volume | 20-40µl |
Electronic Pipette | 20-40µl |
Available dimensions | Seconds, ratio, %, g/L |
Incubation Temperature | 37.0±1.0°C |
Relative humidity | ≤85% |
Precision | PT, APTT, FIB <5%; TT <8%(Normal sample) |
Deviation between channels | <5% |
Power supply | AC100-240V, 50/60Hz |
Net weight | 4.5kg |
Dimension | 345*325*145mm |
Package size | 440*420*350mm |
Gross weight | 7kg |
Technical Features : | |
---|---|
Code | LD1214 |
Testing channel | 4 |
Display | 5 inch screen |
Cuvette incubation positions | 24 |
Reagent incubation positions | 6 |
Wavelength | LED 470nm |
Sample type | Plasma |
Memory | 10000 results storage |
Sample volume | 20-40µl |
Electronic Pipette | 20-40µl |
Available dimensions | Seconds, ratio, %, g/L |
Incubation Temperature | 37.0±1.0°C |
Relative humidity | ≤85% |
Precision | PT, APTT, FIB <5%; TT <8%(Normal sample) |
Deviation between channels | <5% |
Power supply | AC100-240V, 50/60Hz |
Net weight | 5.2kg |
Dimension | 375*335*175mm |
Package size | 440*420*350mm |
Gross weight | 7.5kg |
Technical Features : | |
---|---|
Automatic | Fully automatic |
Throughput | 60 tests/hr |
Assay Items | 22 parameters, 3 parts differential of WBC |
Sample Volume | 13ul(whole blood),20ul(prediluted blood) |
Measuring Principle | Electro-impedance, photometric analysis |
Testing Items | WBC LY LY% MO MO% GR GR%, RBC HGB HCT MCV RDW-SD RDW-CV MCH MCHC PLT MPV PCT PDW, WBC histograms RBC histograms PLT histograms |
Linearity Range | WBC: 0.0-99.9(×10^9/L) RBC:0.0-99.9(×10^12/L) HGB: 0.0-300(g/L) PLT: 0.0-99.9(×10^9/L) |
Display | LCD |
Storage | 200,000 results including histograms |
Output | One RS232 ,one PS2 and two USB. Available for LIS |
Printer | Built-in thermal printer, USB to external printer (Optional) |
Data input | Keypad ( mouse and keypad available) |
QC | Automatically calculates X, SD, CV% and saves date |
Language | English and Spanish. Other language on request |
Power supply | 110/220V±10% , 60/50Hz |
Package Size | 660*480*640mm |
Gross Weight | 38kg |
Technical Features : | |
---|---|
Throughput | 60 tests/hour |
Assay Items | 5 parts, 25 parameters, 2 histograms, 4 scattergrams |
Principle | Tri-angle laser scattering, flow cytometry for WBC differentiation and counting, Impedance for RBC and PLT counting, Cyanide-free method for HGB |
Sample Volume | CBC+Diff mode: 20ul Prediluted mode:20ul |
Sampling Mode | Open mode, built-in barcode scanner |
Parameters | WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, PDW, MPV, PCT, P-LCR, P-LCC, Neu#, Neu%, Lym#, Lym%, Mon#, Mon%, Eos#, Eos%, Bas#, Bas% |
Storage | 60,000 sample results with histograms and scattergrams |
Interface | 4 USB ports, 1LAN port, HL7 protocol, support LIS |
Calibration | Manual and Auto-calibration |
Quality Control | 3 level QC, LJ graph, XB |
Power supply | 110/220V±10% , 60/50Hz |
Package Size | 580*470*590mm |
Gross Weight | 23kg |
USE : Elisa reader is a semi automated bench top instrument designed for clinical immunity-test to measure antibodies . The test is done in an ELISA plate, also known as microplate. The ELISA reader reads the plate. It is mostly used in hospitals and Epidemic prevention stations.
FeaturesDiscription | Parameters |
---|---|
Measurement System | 8- channel optional system |
Range | 0.000-4.000 Abs |
Repeatability | ≤ 0.5% |
Linearity Error | 0.0 - 2.0 ±0.5%,2.0-3.0 ± 1.0%,3.0 -4.0 ±3% |
Filters | Standard 4 Filters,(405, 450, 492, 630 nm),Or 10 Filters maximum 10 |
Display | Touch Screen |
USE : Micro plate washer is an Accessory to Micro plate Reader, It is used to wash the enzymatic plate after detecting.
FeaturesDiscription | Parameters |
---|---|
Washing Head | 8 or 12 channels |
Microplate | 96, 48 hole Microplate |
Repeatability | 1-99 presettable |
Washing Rows Option | 1-12 presettable |
Soak Time | 1-86400 s |
Residual Volume | < 1μl/ well |
USE:The equipment is used to measure concentrations of K+, Na+, C1 and Ca++ and pH value.
FeaturesDiscription | Parameters |
---|---|
Sample | Whole Blood, Serum or Urine |
Sample Volume | 90μl |
Testing time | ≤50s |
LCD Display | 110x65mm |
Working Modes | Normal and Saving |
Power | AC220V (160V- 245V), 50± Hz |
Categories
What our Clients are Saying
The organic reviews not hoax.
Meet Us At
Booth No.: A01
13th to 15th Jun. 2024
IICC Dwarka, New Delhi, India
Booth No.: F11
19th to 21st Jun. 2024
Miami Beach Convention Center, Miami Beach, Florida, USA
Booth No.: 504C Hall 11-16
9th to 12th Jul. 2024
Bogotá, Colombia
Let's profit together!
We are looking for distributors in your area.