These are mobile Warmer mounted on wheels with
fixed baby cradle, lower shelf and 3 drawers storage Cabinet.
Item Code :
NIC700
Technical
Specifications:
Heater Box:
›
Consists of Ceramic Infra Red Heater
650 Watts.
›
The source box can be swivelled to
take X-ray.
›
Due to temp. insulated cover on the
heater box, its exterior surface remains cool even after
long run.
›
The construction of the stainless
steel reflector and Guard rail is such that the complete
cleaning of heater & reflector is possible without
any electrical shock hazards.
Halogen
Examination Lamp (12 Volts, 50 Watts):
›
To provide accurate assessment of
Infant colour and sufficient illumination during procedures.
Baby
Tray (Stainless Steel):
›
Clear acrylic collapsible side panels.
›
Stainless steel baby tray with transparent
slot to incorporate the facility of under surface phototherapy.
›
Acrylic tray and cushion mattress
with head up/down facility.
›
Acrylic X-ray tray with X-ray guide
for positioning the cassette.
›
The design aspects also allow easy
of dismantling baby care area during cleaning or fumigation.
Essential
Attachments:
›
Lower Shelf and 3 Drawer Storage
Cabinet.
›
Side Mounted Monitor tray.
›
Pole for Syringe Pump / Infusion
Pump.
›
S.S. IV Stand.
Item Code :
NIC702
›
Specifications same as above but
only with Skin /manual temperature controller mode.
Infant Radiant Warmer with fixed Baby
Cradle (Deluxe)
This is mobile Warmer mounted on wheels with
fixed baby cradle.
Item Code :
nic706
Mechanical
Specifications:
Heater Box:
›
Consists of Ceramic Infra Red Heater
650 Watts.
›
The source box can be swiveled to
take X-ray.
›
Due to temp. insulated cover on the
heater box, its exterior surface remains cool even after
long run.
›
The construction of the stainless
steel reflector and guard rail is such that the complete
cleaning of heater & reflector is possible without
any electrical shock hazards.
Halogen
Examination Lamp (12 Volts, 50 Watts):
›
To provide accurate assessment of
Infant colour and sufficient illumination during procedures.
Baby
Tray (Stainless Steel):
›
Clear acrylic collapsible side panels.
›
Stainless steel baby tray with transparent
slot to Incorporate the facility of undersurface phototherapy
›
Acrylic tray and cushion mattress
with head up/down facility.
›
Acrylic X-ray tray with X-ray guide
for positioning the cassette.
›
The design aspects also allow easy
of dismantling baby care area during cleaning or fumigation.
Essential
Attachments:
›
2 Lower Shelves.
›
Side Mounted Monitor tray, Pole for
Syringe Pump / Infusion Pump & S.S. IV Stand.
Temp.
Controller to provide thermal regulation with highest
degree of accuracy:
›
Types of temp. controllers : Skin/Air/
manual LCD
Item Code :
NIC707
›
Specifications same as above but
only with Skin /manual temperature controller mode.
Due to temp. insulated cover on the
heater box, its exterior surface remains cool even after
long run.
›
The construction of the stainless
steel reflector and guard rail is such that the complete
cleaning of heater & reflector is possible without
any electrical shock hazards
Halogen
Examination Lamp (12 Volts, 50 Watts):
›
To provide accurate assessment of
Infant colour and sufficient illumination during procedures.
Essential
Attachments:
›
Side Mounted Monitor tray, Pole for
Syringe Pump / Infusion Pump
›
S.S. IV Stand.
Item Code :
NIC717
›
Specifications same as above but
only with Skin /manual temperature controller mode.
Infant Radiant Warmer Stand with Infant
care Trolley (Deluxe)
This is mobile Warmer Stand mounted on wheels
with infant care trolley (Premium).
Item Code :
NIC721
Mechanical
Specifications:
Heater Box:
›
Consists of Ceramic Infra Red Heater
650 Watts.
›
The source box can be swiveled to
take X-ray.
›
Due to temp. insulated cover on the
heater box, its exterior surface remains cool even after
long run.
›
The construction of the stainless
steel reflector and guard rail is such that the complete
cleaning of heater & reflector is possible without
any electrical shock hazards.
Halogen
Examination Lamp (12 Volts, 50 Watts):
›
To provide accurate assessment of
Infant colour and sufficient illumination during procedures.
Essential
Attachments:
›
Side Mounted Monitor tray, Pole for
Syringe Pump / Infusion Pump.
›
S.S. IV Stand.
Infant
Care Trolley Premium:
›
Clear acrylic collapsible side panels
to assess an infant from all sides.
›
Stainless steel baby tray with transparent
slot to incorporate the facility of under surface phototherapy.
›
Acrylic tray and cushion mattress
with head up/down facility.
›
Acrylic X-ray tray with X-ray guide
for positioning the cassette.
›
Two Lower shelves.
›
Mounted on wheel 4"
›
The design aspects also allow easy
of dismantling baby care area during cleaning or fumigation.
Item Code :
NIC723
›
Specifications same as above but
only with Skin /manual temperature controller mode.
This unit is to be fixed on the wall above baby
care area.
Item Code :
NIC726
Mechanical
Specifications:
Heater Box:
›
Consists of Ceramic Infra Red Heater
650 Watts.
›
The source box can be swiveled to
take X-ray.
›
Due to temp. insulated cover on the
heater box, its exterior surface remains cool even after
long run.
›
The construction of the stainless
steel reflector and guard rail is such that the complete
cleaning of heater & reflector is possible without
any electrical shock hazards.
Halogen
Examination Lamp (12 Volts, 50 Watts):
›
To provide accurate assessment of
Infant colour and sufficient illumination during procedures.
Essential
Attachments:
›
S.S. IV Stand.
Temp.
Controller to provide thermal regulation with highest
degree of accuracy:
›
Two types of temp. controllers :
Skin/Air/ manual LCD.
Item Code :
NIC728
›
Specifications same as above but
only with Skin /manual temperature controller mode.
Infant Radiant Warmer Wall Mounted with
Trolley (Deluxe)
The warmer unit is to be fixed on the wall above
infant care trolley.
Item Code :
NIC731
Mechanical
Specifications:
Heater Box:
›
Consists of Ceramic Infra Red Heater
650 Watts.
›
The source box can be swiveled to
take X-ray.
›
Due to temp. insulated cover on the
heater box, its exterior surface remains cool even after
long run.
›
The construction of the stainless
steel reflector and guard rail is such that the complete
cleaning of heater & reflector is possible without
any electrical shock hazards.
Halogen
Examination Lamp (12 Volts, 50 Watts):
›
To provide accurate assessment of
Infant colour and sufficient illumination during procedures.
Essential
Attachments:
›
S.S. IV Stand.
Infant
Care Trolley Premium:
›
Clear acrylic collapsible side panels
to assess an infant from all sides.
›
Stainless steel baby tray with transparent
slot to incorporate the facility of undersurface phototherapy.
›
Acrylic tray and cushion mattress
with head up/down facility.
›
Acrylic X-ray tray with X-ray guide
for positioning the cassette.
›
Two Lower shelves.
›
Mounted on wheel.
›
The design aspects also allow easy
of dismantling baby care area during cleaning or fumigation.
Temp.
Controller to provide thermal regulation with highest
degree of accuracy.:
›
Types of temp. controllers : Skin/Air/
manual LCD.
Item Code :
NIC733
›
Specifications same as above but
only with Skin /manual temperature controller mode.
These are mobile Warmer mounted on wheels with
fixed baby cradle, lower shelf and 3 drawers storage Cabinet.
Item Code :
NIC801
Technical
Specifications:
Heater Box:
›
Consists of Ceramic Infra Red Heater
650 Watts.
›
Metallic overhead heater box.
›
The construction of the stainless
steel reflector and Guard rail is such that the complete
cleaning of heater & reflector is possible without
any electrical shock hazards.
Halogen
Examination Lamp (12 Volts, 50 Watts):
›
To provide accurate assessment of
Infant colour and sufficient illumination during procedures.
Baby
Tray (Stainless Steel):
›
Clear acrylic collapsible side panels.
›
Stainless steel baby tray with transparent
slot to incorporate the facility of under surface phototherapy.
›
Acrylic tray and cushion mattress
with head up/down facility.
›
Acrylic X-ray tray with X-ray guide
for positioning the cassette.
›
The design aspects also allow easy
of dismantling baby care area during cleaning or fumigation.
Essential
Attachments:
›
Lower Shelf and 3 Drawer Storage
Cabinet.
›
S.S. IV Stand.
Temp.
Controller to provide thermal regulation with highest
degree of accuracy:
›
Types of temp. controllers : Skin/Air/
manual LCD
Item Code :
NIC804
›
Specifications same as above but
only with Skin /manual temperature controller mode.
Infant Radiant Warmer with fixed Baby
Cradle (Standard)
This is mobile Warmer mounted on wheels with
fixed baby cradle.
Item Code :
NIC807
Mechanical
Specifications:
Heater Box:
›
Consists of Ceramic Infra Red Heater
650 Watts.
›
Metallic overhead heater box.
›
The construction of the stainless
steel reflector and guard rail is such that the complete
cleaning of heater & reflector is possible without
any electrical shock hazards.
Halogen
Examination Lamp (12 Volts, 50 Watts):
›
To provide accurate assessment of
Infant colour and sufficient illumination during procedures.
Baby
Tray (Stainless Steel):
›
Clear acrylic collapsible side panels.
›
Stainless steel baby tray with transparent
slot to Incorporate the facility of undersurface phototherapy.
›
Acrylic tray and cushion mattress
with head up/down facility.
›
Acrylic X-ray tray with X-ray guide
for positioning the cassette.
›
The design aspects also allow easy
of dismantling baby care area during cleaning or fumigation.
Essential
Attachments:
›
Lower Shelf.
›
S.S. IV Stand.
Temp.
Controller to provide thermal regulation with highest
degree of accuracy:
›
Types of temp. controllers : Skin/Air/
manual LCD
Item Code :
NIC810
›
Specifications same as above but
only with Skin /manual temperature controller mode.
The construction of the stainless
steel reflector and guard rail is such that the complete
cleaning of heater & reflector is possible without
any electrical shock hazards.
Halogen
Examination Lamp (12 Volts, 50 Watts):
›
To provide accurate assessment of
Infant colour and sufficient illumination during procedures.
Essential
Attachments:
›
Lower Shelf.
›
S.S. IV Stand.
Item Code :
NIC818
›
Specifications same as above but
only with Skin /manual temperature controller mode.
Infant Radiant Warmer Stand with Infant
care Trolley (Standard)
This is mobile Warmer Stand mounted on wheels.
Item Code :
NIC822
Mechanical
Specifications:
Heater Box:
›
Consists of Ceramic Infra Red Heater
650 Watts.
›
Metallic overhead heater box.
›
The construction of the stainless
steel reflector and guard rail is such that the complete
cleaning of heater & reflector is possible without
any electrical shock hazards.
Halogen
Examination Lamp (12 Volts, 50 Watts):
›
To provide accurate assessment of
Infant colour and sufficient illumination during procedures.
Essential
Attachments:
›
S.S. IV Stand.
Infant
Care Trolley Standard:
›
Clear acrylic collapsible side panels
to assess an infant from all sides.
›
Stainless steel baby tray with transparent
slot to incorporate the facility of under surface phototherapy.
›
Acrylic tray and cushion mattress
with head up/down facility.
›
Acrylic X-ray tray with X-ray guide
for positioning the cassette.
›
Two Lower shelves.
›
Mounted on wheel 2".
›
The design aspects also allow easy
of dismantling baby care area during cleaning or fumigation.
Item Code :
NIC824
›
Specifications same as above but
only with Skin /manual temperature controller mode.
Infant Warmers are designed to provide
advance warming capabilities while using one touch operations
to simplify procedures.
›
Immediately after delivery the new
born baby experiences some degree of thermal instability
as it comes from the mothers womb which has the stable
environment to the cooler environment of the delivery
room.
›
Available with a choice of thermal
control system Skin/Manual control.
›
Two function control modes provide
the clinician more flexibility while optimizing the
thermal environment.
›
In addition, the Skin/ Air temperature
display is larger then the other set temperature display.
›
Advance microprocessor controlled
with self-check on the electronic circuit.
›
Digital display of patient temperature
and soft touch display of control temperature.
›
Skin Temperature can be converted
from Celsius to Fahrenheit by the push of a button.
›
The spacious baby bed incorporates
easily drop down sides for maximum access to the patient.
›
The control panel is also the heart
for a completely integrated alarm system with both audible
and visual indicators in the event of Probe Fail, Skin
High, Skin Low, Power Fail, Heater Fail.
Manual
Mode:
›
Facility to converting the
warmer from servo mode to manual mode for non-stop
working.
›
In Manual mode warmer will
start from 40% heat and can be increased upto
99% according to usage.
Heater
Assembly:
›
The Heater assembly located
above the cente r of the support structure consists
of radiant heater and reflector with inbuilt halogen
examination lamp for assessment of Infant Color.
The digital, microprocessor-based
controller comes standard with a full spectrum of features.
›
The Tiana Open care system comes
complete with automatic Manual and baby (Servo) modes.
›
Two function control models provide
the clinician more flexibility while optimizing the
thermal environment.
›
Skin temperature display is larger
then other set temperature display.
›
Skin temperature display can be converted
from °C to °F by the push of a buttom.
›
A full complement of alarm provides
safety and convenience, with both audible and visual
indicators in the event of: High Temp. / Low Temp.,
Set High / Set Low, Probe Failure, Power Failure.
›
The system automatically starts the
heating from 40% in manual mode and the same can be
changed through settings upto 99%.
›
The High & Low Temp. alarm settings
can be adjusted according to the patient condition.
The Radiant Warmer Features an independent
ambient temperature probe which maximizes the heating
efficiency across the range of operating temperature.
A big LCD is provided for more
specific information & visualization of the heater
power in manual and servo modes.
The system automatically converts
from servo mode to manual mode in case of probe failure
thus providing non stop working of the unit.
The spacious baby bed incorporates
easily drop down sided for maximum access to the patient.
Heater
Assembly:
›
The heater assembly located
above the center of the support structure consists
of an integral examination light and a 650 Watts
heating system for quick warming and even distribution
of heat on the baby bed.
The First
Breath:
›
The open care system combines
virtually all the technology a caregiver may need
in situation needed for resuscitation.
The neonate can be supplied
with a constant oxygen flow through the Oxygen
humidifier when connected to an oxygen cylinder
(optional).
The motorized slow suction
can be used with a simple flip of a switch
A digital Apgar timer is standard,
which signals when 1,5 and 10 minutes have elepsed.
The digital, microprocessor-based
controller comes standard with a full spectrum of features.
›
The Tiana Open care system comes
complete with automatic Manual and baby (Servo) modes.
›
Two function control models provide
the clinician more flexibility while optimizing the
thermal environment.
›
Dual digital temperature display
is larger then other set temperature display.
›
Skin temperature display can be converted
from °C to °F by the push of a bottom.
›
A full complement of alarm provides
safety and convenience, with both audible and visual
indicators in the event of: High Temp. / Low Temp.,
Set High / Set Low, Probe Failure, Power Failure.
›
The system automatically starts the
heating from 40% in manual mode and the same can be
changed through settings upto 99%. This changed power
will remain for 15 minutes only and after that it will
become 40% automatically.
›
The High & Low Temp. alarm settings
can be adjusted according to the patient condition.
The Radiant Warmer Features an independent
ambient temperature probe which maximizes the heating
efficiency across the range of operating temperature.
A big LCD is provided for more
specific information & visualization of the heater
power in manual and servo modes.
The system automatically converts
from servo mode to manual mode in case of probe failure
thus providing non stop working of the unit.
The spacious baby bed incorporates
easily drop down sided for maximum access to the patient.
Heater
Assembly:
›
The heater assembly located
above the center of the support structure consists
of an integral examination light and a 650 Watts
heating system for quick warming and even distribution
of heat on the baby bed.
The First
Breath:
›
The open care system combines
virtually all the technology a caregiver may need
in situation needed for resuscitation.
The neonate can be supplied
with a constant oxygen flow through the Oxygen
humidifier when connected to an oxygen cylinder.