CT Scanner


NCT16 : CT Scan 16 Slices
Lower kV CT Angiography
  • Lower kV presents a diagnostic advantage in CT Angiography by decreasing radiation dose and contrast material volume, which is particularly beneficial for renally impaired patients, minimizing the need for time-consuming and high-cost after-care procedures (e.g., monitoring and renal function tests)
100 kV Large Range CTA
  • Stent surgery follow up exam, severe stenosis of celiac trunk.
  • CTDIvol: 7.5 mGy , DLP: 542.7 mGy*cm, Effective dose: 8.14 mSv; Scan length: 701 mm
100 kV Abdomen CTA
  • Reexamination after aortic dissection stenting.
  • CTDIvol: 7.5 mGy, DLP: 536 mGy*cm, Effective dose: 8.04 mSv; Scan length: 692 mm
80 kV Carotid CTA
  • Right vertebral artery narrow.
  • CTDIvol: 6.4 mGy, DLP: 241.1 mGy*cm, Effective dose: 0.75 mSv
HD Imaging Chain
  • Market-leading high definition imaging solutions and innovations are brought together in NCT series, delivering clear visualization of subtle structures, early detection of micro-lesions and exceptional clinical outcomes.
Excellent Clinical Routine
  • Narang Medical is continuously innovating state-of-the-art Reconstruction Algorithms for image clarity.
  • For neuro imaging, NCT series delivers the speed and accuracy, enabling fast life-saving interveution decisions with detailed display of brain structures.
  • For lung imaging, low-dose high definition acquisition enables CT lung cancer screening more accessible to high-risk, asymptomatic individuals.
  • For abdomenal imaging, NCT series's balanced imaging chain offers defined edges and natural contouring for every clinical anatomy and lesions, essentially enhancing diagnostic confidence.
  • For orthopedic imaging, fast scan time, long scanning range, consistent image quality with a significant dose reduction benefit are the keys to reliable diagnostic outcomes for trauma patients who are potentially in a lot of pain and require immediate care.
Spectral Imaging
  • With the assistance of Spectral Imaging, NCT series allows acquisition of both anatomical and functional information, providing better contrast images, metal artifact reduction, material separation and affirmation of eff-Z number, resulting in major gains in specificity and diagnostic accuracy.
Gout Virtualization
  • With an examination set up as simple as a regular spiral scan, Spectral Imaging adds valuable quantitative information to the morphology of conventional CT scans, providing material decomposition that can prove useful for gout visualization.
Metal Artifact Reduction
  • Imaging patients with metal implants has long been a challenge for all modalities. NCT series powered by Spectral Imaging can significantly reduce beam hardening artifacts through monochromatic energy synthesis, resulting in outstanding image quality with valuable diagnostic information.
Energy Saving Design
  • NCT series utilizes intelligent power management design to optimize power consumption during scanning and reduces stand-by power consumption, in combination with effective electricity transmission system, resulting in 12% power usage reduction. Decreased energy requirements lowers operational costs while minimizing the environmental footprint contributing to a greener planet.
Technical Specifications:

Key data:

  • Tube heat capacity…………………………3.5 MHU
  • Generator power…………………….….....…32 kW
  • kV steps………………………………………...……..60, 70, 80, 100, 120, 140 kV
  • mA range………………………………………...……10-320 mA
  • Slices………………………………………………………16 slices
  • Rotation time…………………………………..…0.71 s/360°
  • Spatial resolution………………………………15 lp/cm @ 0% MTF
  • Low contrast resolution…………………2 mm @ 0.3%

NCT32 : CT Scan 32 Slices
Lower kV CT Angiography
  • Lower kV presents a diagnostic advantage in CT Angiography by decreasing radiation dose and contrast material volume, which is particularly beneficial for renally impaired patients, minimizing the need for time-consuming and high-cost after-care procedures (e.g., monitoring and renal function tests)
100 kV Large Range CTA
  • Stent surgery follow up exam, severe stenosis of celiac trunk.
  • CTDIvol: 7.5 mGy , DLP: 542.7 mGy*cm, Effective dose: 8.14 mSv; Scan length: 701 mm
100 kV Abdomen CTA
  • Reexamination after aortic dissection stenting.
  • CTDIvol: 7.5 mGy, DLP: 536 mGy*cm, Effective dose: 8.04 mSv; Scan length: 692 mm
80 kV Carotid CTA
  • Right vertebral artery narrow.
  • CTDIvol: 6.4 mGy, DLP: 241.1 mGy*cm, Effective dose: 0.75 mSv
HD Imaging Chain
  • Market-leading high definition imaging solutions and innovations are brought together in NCT series, delivering clear visualization of subtle structures, early detection of micro-lesions and exceptional clinical outcomes.
Excellent Clinical Routine
  • Narang Medical is continuously innovating state-of-the-art Reconstruction Algorithms for image clarity.
  • For neuro imaging, NCT series delivers the speed and accuracy, enabling fast life-saving interveution decisions with detailed display of brain structures.
  • For lung imaging, low-dose high definition acquisition enables CT lung cancer screening more accessible to high-risk, asymptomatic individuals.
  • For abdomenal imaging, NCT series's balanced imaging chain offers defined edges and natural contouring for every clinical anatomy and lesions, essentially enhancing diagnostic confidence.
  • For orthopedic imaging, fast scan time, long scanning range, consistent image quality with a significant dose reduction benefit are the keys to reliable diagnostic outcomes for trauma patients who are potentially in a lot of pain and require immediate care.
Spectral Imaging
  • With the assistance of Spectral Imaging, NCT series allows acquisition of both anatomical and functional information, providing better contrast images, metal artifact reduction, material separation and affirmation of eff-Z number, resulting in major gains in specificity and diagnostic accuracy.
Gout Virtualization
  • With an examination set up as simple as a regular spiral scan, Spectral Imaging adds valuable quantitative information to the morphology of conventional CT scans, providing material decomposition that can prove useful for gout visualization.
Metal Artifact Reduction
  • Imaging patients with metal implants has long been a challenge for all modalities. NCT series powered by Spectral Imaging can significantly reduce beam hardening artifacts through monochromatic energy synthesis, resulting in outstanding image quality with valuable diagnostic information.
Energy Saving Design
  • NCT series utilizes intelligent power management design to optimize power consumption during scanning and reduces stand-by power consumption, in combination with effective electricity transmission system, resulting in 12% power usage reduction. Decreased energy requirements lowers operational costs while minimizing the environmental footprint contributing to a greener planet.
Technical Specifications:

Key data:

  • Tube heat capacity…………………………3.5 MHU
  • Generator power…………………….….....…32 kW
  • kV steps………………………………………...……..60, 70, 80, 100, 120, 140 kV
  • mA range………………………………………...……10-320 mA
  • Slices………………………………………………………32 slices
  • Rotation time…………………………………..…0.71 s/360°
  • Spatial resolution………………………………15 lp/cm @ 0% MTF
  • Low contrast resolution…………………2 mm @ 0.3%

Categories



What our Clients are Saying

The organic reviews not hoax.


Meet Us At


India Healthcare 2024

Booth No.: A01
13th to 15th Jun. 2024
IICC Dwarka, New Delhi, India

FIME 2024

Booth No.: F11
19th to 21st Jun. 2024
Miami Beach Convention Center, Miami Beach, Florida, USA

MEDITECH 2024

Booth No.: 504C Hall 11-16
9th to 12th Jul. 2024
Bogotá, Colombia

Become Our Distributor

Let's profit together!
We are looking for distributors in your area.

Note: CT Scanner - Manufacturer CT Scanner. We manufacture and export high quality CT Scanner and other CT Scanner Equipments, CT Scanner Products & Supplies. Trust NET brand for Surgical Instruments, Medical Supplies, Hospital Equipments, Laboratory Products & Goods.

Narang Medical Limited

Narang Tower, 46 Community Centre, Naraina Ph-I, New Delhi - 110028, India.

Call us: +91-11-45554000

Mail Us: NET@narang.com

Associate Sites


© Narang Medical Limited. All Rights Reserved

Narang Medical Reviews

CT Scanner

CT Scanner Manufacturers

CT Scanner Suppliers

CT Scanner Manufacturer India