Construction : Triple walled with steam jacket, Inner chamber, and separate
boiler are made up of Heavy gauge Stainless steel Sheet with leakproof arc
welding. The Autoclave has a single-piece door made of stainless steel 316/304. The backplate and ring are also made of thick stainless steel sheets. All the sterilizers are hydraulically tested to 4kg/cm2 pressure. Mounted on a tubular steel frame with ground leveling screwed flanges. The Outer jacket is wrapped with glass wool to minimize the heat losses due to radiation and is covered by a polished stainless steel sheet.
The Steam Generator is made of a heavy stainless steel sheet. Heavy ring mounted in front of the boiler with folding thick stainless steel plate is fitted with heating elements and low water level cutoff device to protect the former from burning out dry. The front folding plate system provides easy cleaning of the deposited scale on the elements and the walls for long life and efficiency. Fitted with water gauge glass for water level indication, water inlet, and outlet valves.
Pressure Control Device Device “PIEZOSTAT” is incorporated in electrically operated sterilizers. It economizes on power consumption and reduces the frequent opening of the steam release valve and thus prevents the release of steam in the room, It cuts off the power supply to heaters when the set pressure is achieved and re-energizes the heating elements when pressure falls below the set point. The heating element is Flanged type is made of high-grade SS 304 material.
Safety Door : Sterilizer has hinged self-locking single piece thick S.S. 316/304 plate door which cannot be opened when
under pressure. The self-locking device automatically disengages the thread mechanism when the sterilizer is under pressure
to preclude any eventuality of an accident.
Features :
- Triple Safety: The Sterilizer is provided with triple safety features. At the boiler level by a "Piezostat" which automatically limits the pressure to the required set value and a spring-loaded safety valve in case of its failure which releases the steam to keep pressure within the safety limits. At the chamber level, a spring-loaded safety valve and a dead weight release
valve to release the steam in case the pressure exceeds the safety limit. All these safety features function independent of
one another and sequentially i.e. one takes over the charge in case of the other’s failure.
- Prevents the discharge line from choking. The plug is easily removable for daily cleaning.
- Powerful Ejector for drying sterilized linen circulates air throughout the chamber. The circulating air passes through a
corrosion-resistant metallic wool filter.
- Digital Display is provided to show the chamber temperature.
- Automatic Vacuum breaker is provided to break vacuum in case of formation of vacuum due to steam condensation.
MODEL SPECIFICATIONS |
MODEL |
AU905-75 |
AU905-98 |
AU905-138 |
AU905-177 |
AU905-251 |
AU905-353 |
Capacity |
75 L |
98 L |
138 L |
177 L |
251 L |
353 L |
Diameter |
400 mm |
450 mm |
400 mm |
500 mm |
500 mm |
600 mm |
Depth |
600 mm |
600 mm |
1100 mm |
900 mm |
1280 mm |
1250 mm |
Operating Temperature |
121 to 134°C |
121 to 134°C |
121 to 134°C |
121 to 134°C |
121 to 134°C |
121 to 134°C |
Operating Pressure |
15 - 30 PSI |
15 - 30 PSI |
15 - 30 PSI |
15 - 30 PSI |
15 - 30 PSI |
15 - 30 PSI |
Power Consumption |
9 Kw |
9 Kw |
18 Kw |
12 Kw |
18 Kw |
24 Kw |
Voltage |
440V/50Hz, 3 Ph |
440V/50Hz, 3 Ph |
440V/50Hz, 3 Ph |
440V/50Hz, 3 Ph |
440V/50Hz, 3 Ph |
440V/50Hz, 3 Ph |
All Autoclaves Hydraulically tested to 4 kg/cm2 pressure. |
Your feedback greatly assists us in enhancing our services to better serve you.