Function Features :
  • Small in size, light and high irradiation
  • LED Blue light as the radiant source is irradiating uniformly and efficient.
  • Circle 360 double sides for more effective irradiation.
  • Two phototherapy mode: up side phototherapy and down side phototherapy, can be use separately.
  • The electronic ballast makes the power supply adaptable and the power factor high.
  • Therapy time of phototherapy units from up and down side are displayed separately.
  • Automatically record each therapy time and total used therapy time
  • Air temperature and skin temperature separately displayed
  • Power off memory, silence key for alarm, key-locking and self-examination function.
  • Four alarm functions for safety: Power failure, probe failure, over temperature, fan failure
  • Function of setting up the count-down working time.
  • It is convenient to know the therapy of the infant through observation ports on both sides.
  • Adopt air spring structure and the hood is easy to open and close.
  • The aluminum-magnesium alloy is applied on the base , with two drawers and tray.

Technical Data :
Power Supply : AC220V±10%, 50Hz±2%
Power Input : ≤400VA
Blue light wavelength : 420nm ~ 490nm
Circle 360 light radiation : 3700μW/cm²
Up side light radiation : 3300μW/cm²
Down side light radiation : 2400μW/cm²
Life span of blue light tube : >20000hours
Air temperature display range : 0~45 0°C
Skin temperature display range : 0~45 0°C
Time accuracy : 1min/2h
Count-up time range : 0~99.9 hours
Count-down time range : 1min~99.9hours
Total cumulative time : 999999hours
Mattress size : 613x300mm
Four alarm functions : Power failure, probe failure,over temperature, fan failure

Working environment :
Ambient temperature : +18°C~+30°C
Relative humidity : 30%~75%
Atmospheric pressure : 700hpa~1060hpa

Standard configuration :
  • Main body (including the Radiant source, Control system, Infant bed, Bracket).
  • I.V. Pole, Skin temperature sensor, Air temp sensor.
  • Tray, Mattress, Transparent protector, Castors, Two drawers.

Optional Parts :
  • Gel mattress and bed

Transport and Storage :
Environment Temperature : -40°C~ +55°C
Environment Relative Humidity : ≤95%
Atmospheric Pressure : 500~1060hPa

Package :
Each unit is packed one case Size : 140cm x 84cm x 90cm
Gross weight : <80KG

They have been A+ in quality, pricing and after sales service...

Quick Response :

Meet us at:
  • Africa Health 2018
  • 29th to 31st May, 2018
  • at Gallagher Convention Centre, Midrand, Johannesburg, South Africa.
  • Booth No. 3C20
Fix Appointment
  • IMMEXLS - Miami, FL, USA.
  • 23rd to 24th Oct, 2018
  • at james L Knight Center, Miami, FL, USA.
  • Booth N0. 23 & 24
Fix Appointment
  • MEDICA 2018
  • 12th to 15th Nov, 2018
  • at Dusseldorf Fairgrounds, Germany.
Fix Appointment
  • Arab Health 2019
  • 28th to 31st Jan, 2019
  • at Dubai International Convention and Exhibition Centre, Dubai, U.A.E.
Fix Appointment

View All Exhibitions         

Exhibitions     |     Send Query

Infant Phototherapy Unit


Manufacturer Suppliers

Phototherapy Units - Orange Series