The NET anesthesia machine are used by anesthesiologists, nurse anesthetists to support the administration of anesthesia. It is designed to provide an accurate and continuous supply of medical gases (such as oxygen and nitrous oxide), which are mixed with an accurate concentration of anaesthetic vapour (such as isoflurane), and then delivered to the patient at a safe pressure and flow.
Basic Features:
Optional : Patient monitor, Anesthetic gas monitor, AGSS, O2 /AIR blender, Hand held ETCO2 module.
Ventilation mode | IPPV (VCV)/A/C (SIPPV) SIMV / MANUAL |
Frequency | 1bpm - 100bpm |
I/E | 0.2s - 6s 2:1 - 1:6 |
Tidal Volume VT | 0ml - 1500ml |
MV | >18L/min |
PEEP | 0cmH2O - 30cmH2O |
PTr | -20 2O - 20cmH2O |
Ftr, Pc, TIP | - |
Apnea Ventilation | OFF,5s - 60s |
SIGH | 1/100 - 5/100 |
Graphical display | 1. P-T(pressure – time) 2. F-T(flow – time) " |
Basic Features:
Optional : Patient monitor, Anesthetic gas monitor, AGSS,Yoke, ACGO, ETCO2 module on screen.
Ventilation mode | IPPV (VCV) / A/C (SIPPV) SIMV / MANUAL |
Frequency | 1bpm - 100bpm |
I/E | 0.2s - 6s 2:1 - 1:6 |
Tidal Volume VT | 0ml - 1500ml |
MV | >18L/min |
PEEP | 0cmH2O - 30cmH2O |
PTr | -20 2O - 20cmH2O |
(Ftr), (Pc) , ( TIP) | (OFF,0.5L/min - 30L/min), (-), (0-3s) |
Apnea Ventilation | OFF,5s - 60s |
SIGH | 1/100 - 5/100 |
Graphical display | 1. P-T(pressure – time) 2. F-T(flow – time) " |
Same as AN314 but with Electronic Valve & Ventilation modes includes pressure control and volume control limit.
Ventilation mode | IPPV (VCV) / A/C (SIPPV) PCV SIMV SIGH MANUAL |
Frequency | 1bpm - 100bpm |
I/E | 0s - 12s 4:1 - 1:8 |
Tidal Volume VT | 0ml - 1500ml |
MV | >18L/min(Adult) >10L/min(Children) |
PEEP | 0cmH2O - 30cmH2O |
PTr | -20 2O - 20cmH2O |
Ftr | OFF, 1L/min - 30L/min |
Pc | 5cmH2O - 60cmH2O |
TIP | 0 - 6s |
Apnea Ventilation | OFF, 5s - 60s |
SIGH | 1/100 - 5/100 |
Graphical display | 1. P-T(pressure – time) 2. F-T(flow – time) 3. P-V loop (pressure – volume loop) |
Basic Features :
OPTIONAL: Patient monitor, Anesthetic gas monitor, AGSS, Yoke.
AN330A : Same as AN330 but with patient monitor
AN330B : Same as AN330A but with Anesthetic gas monitor, AGSS, Yoke-3.
Ventilation mode | IPPV (VCV) / A/C (SIPPV) PCV SIMV SIGH MANUAL |
Frequency | 1bpm - 100bpm |
I/E | 4:1 - 1:8(Adult) 2:1 - 1:8(Children) |
Tidal Volume VT | 0ml - 1500m |
MV | >18L/min(Adult) >10L/min(Children) |
PEEP | 0cmH2O - 30cmH2O |
PTr | -20cmH2 O - 0cmH2O |
Ftr | OFF, 0.5L/min - 30L/min |
Pc | 5cmH2O - 60cmH2O |
TIP | 0 - 6s |
Apnea Ventilation | OFF, 5s - 60s |
SIGH | 1/100 - 5/100 |
Graphical display | 1. P-T(pressure – time) 2. F-T(flow – time) 3. P-V loop (pressure – volume loop) 4. V-T(volume – time ) 5. ETCO2 -T (End-tidal Co2 - time) |
Basic Features:
Safety:
*AN300 Anesthesia Ventilator is outside the frame
Ventilation Modes | Flow meter | Flow meter | Tidal volume (Vt) | Frequency (Freq) | I/E |
---|---|---|---|---|---|
IPPV, Manual | O2(0.1-10L/min) N2O(0.1-10L/min) |
(0.1-10L/min) | 50 - 1600ml | 1-90bpm | 4:1 -6:1 |
Basic Features:
Safety:
*AN305 Anesthesia Ventilator is inside the frame
Ventilation Modes | Flow meter | Flow meter | Tidal volume (Vt) | Frequency (Freq) | I/E |
---|---|---|---|---|---|
IPPV, Manual | O2(0.1-10L/min) N2O(0.1-10L/min) |
(0.1-10L/min) | 50 - 1600ml | 1-90bpm | 4:1 -6:1 |
Categories
What our Clients are Saying
The organic reviews not hoax.
Meet Us At
29th Jan. to 01st Feb. 2024
Dubai World Trade Centre, Dubai, U.A.E
13th to 15th Feb. 2024
Hall A-F, Booth No. 127
San Francisco, California, USA.
19th to 21st Jun. 2024
Miami Beach Convention Center, Miami Beach, Florida, USA
Let's profit together!
We are looking for distributors in your area.