Veterinary Anesthesia System is widely applied to veterinary clinics & hospitals. Model designed for safe, simple and controllable inhalation anesthesia for animals. The Veterinary Anesthesia System provides rapid control of anesthetic depth with little resistance to respiration from high to low acuity, simple to complex cases, small to big animals, like Dogs, Cats, Rabbits, Mice, Birds, etc.
Specifications:
| Ventilation Modes | |
|---|---|
| IPPV; A/C; PCV; SIMV; SIGH, MANUAL | |
| Ventilator parameter range | |
| Flow meter | O2 (0.1-10L/min) N2O (0.1-10L/min) |
| Rapid oxygen supply | 25L/min-75L/min |
| Tidal volume(Vt) | 0, 20 mL ~ 1500 mL |
| Frequence(Freq) | 1/min ~100/min |
| Monitored Parameters | |
| Frequence(Freq) | 0 /min ~ 100 /min |
| Tidal volume(Vt) | 0 mL ~ 2000 mL |
| MV | 0 L/min ~ 100 L/min |
| Oxygen concentration | 15 % ~ 100 % |
| Oscillogram | |
| P-T(pressure – time) | |
| F-T(flow – time) | |
| P-V loop (pressure – volume loop) | |
| V-T(volume – time) | |
| ETCO2-T(ETCO2-time) | |
| Working conditions | |
| Gas source | O2, N2O |
| Pressure | 280kPa-600kPa |
Specifications:
| Ventilation modes | IPPV; A/C; SIMV; SIGH ,MANUAL |
| Flow meter | O2 (0-5L/min) |
| Rapid oxygen supply | 25L/min-75L/min |
| Tidal volume(Vt) | 0, 20 mL ~ 1500 mL |
| Frequence(Freq) | 1/min ~100/min |
| Pressure triggering | |
| sensitivity(PTr) | -20 cmH2O~ 0 cmH2O (Based on PEEP) |
| Flow trigger sensitivity | 0.5 L/min ~ 30 L/min |
| Apnea Ventilation | OFF,5 s ~ 60 s |
| Pressure Limit | 20 cmH2O~100 cmH2O |
Specifications:
Technical Specification:
| Flow meter | O2 (0~5L/min) |
| Rapid oxygen supply | 25L/min-75L/min |
| Monitoring parameter | |
| Airway pressure | 0 cmH2O~100cmH2O |
| Working condition | |
| Gas source | O2 |
| Pressure | 280kPa-600kPa |
The anesthesia system makes a good performance in operation room with acuity from high to low, applicable for cases from simple to complex. The good performance is based on high security, high accuracy, high stability and accurate monitoring.
Specifications:
Technical Specification:
| Flow meter | O2 (0~5L/min |
| Rapid oxygen supply | 25L/min-75L/min |
| Monitoring parameter | |
| Airway pressure | 0 cmH2O~100cmH2O |
| Working condition | |
| Gas source | O2 |
| Pressure | 280kPa-600kPa |
Specifications:
Technical Specification:
| Flow meter | O2 (0~5L/min |
| Working condition | |
| Gas source | O2 |
| Pressure | 280kPa-600kPa |
Categories
Meet Us At
Become an Authorized NET Brand Distributor
Let's profit together! We are looking for distributors in your area.
Most Searched items
Case, Aluminium, for Midwife Kit , approx 305 x 216 x150 mm ...
An umbilical cord clamp is a sterile, lightweight plastic device designed with two interlocking...
Made from pure natural rubber Latex for greater finger dexterity ...