Application:
Spirometer is used to assess how well your lungs work by measuring how much air you inhale / exhale and how quickly you exhale. It is used to diagnose asthma, chronic obstructive pulmonary disease (COPD) and other conditions that affect breathing.
Basic Features:
Technical Features :
Display Screen | Diagonal line 5.7inches |
Monochrome LCD | |
Resolution 320*240 | |
Measuring range | Capacity range: 0L ~ 9L Flow velocity range: 0 ~ 14L / s |
Accuracy | Capacity: 0L ~ 1.6L (±50ml) 6L ~ 9L (±3%) |
Flow rate: 5% or 0.2L / s | |
Respiratory rate: 4 / 20 ~ / min (±1 / min) 20 / 60 / min (error: ± 5%) | |
Measuring time limit and degree | Vital capacity: every 50s, measuring 3 |
FVC: per second, 25s, measuring 3 | |
The maximum ventilation volume: every 12 seconds, measuring 3 | |
Packing size | 2 Kg, 284*209*84mm |
Optional | Software to connect to PC |
Basic Features:
Technical Features | |
---|---|
Flow rate | 0.1~1500 mL/h (0.1 mL/h step, if the value is 100 mL/h or above, the step is 1mL/h ) |
Bolus rate | 600~1000 mL/h (Adjustable) |
KVO rate | 0.1 mL/h~5 mL/h (Adjustable) |
Accuracy of infusion | <±5%(<±3% for calibrated infusion apparatus) |
Bubble detector | Ultrasonic detection method |
Detection sensitivity | 25 micro L |
Infusion history records | 1500 pcs |
Preset volume | 1~9999 mL |
Display range of totally delivered volume | 0~9999 mL(0.1 mL step, if the value is above 100 mL, the step is 1 mL ) |
Power | Built in battery: DC12 V, 2300mAH,in fully charged status, the device can work for more than 6 hours at the rate of 25mL/h |
Basic Features:
Technical Features | |
---|---|
Bolus | 300 ~ 1200 ml/h |
Flow rate range | 0.1~1200 ml/h |
Volume limit | 1-9999 ml |
Accuracy | ±5% |
KVO flow rate | 1 ~ 5 ml/h |
Power supply | AC100-240V, 50/60 Hz, 25VA |
Battery | Rechargeable lithium polymer battery, 7.4 V, 1650mAh |
Power | 25VA |
Weight | 1.6 Kg |
Dimension | 145×100×120 mm |
Infusion mode | Rate mode, drip mode, time mode, body weight mode |
Basic Features:
Technical Features :
CODE | DP2075B |
---|---|
Bolus | 699ml/h |
Flow rate | 1 mL/h~699 mL/h |
Volume Limit | 1 mL~9999 mL |
Accuracy | < ± 5% |
KVO rate | 1 mL/h |
Occlusion | 100 kPa~300 kPa |
Power supply | 100-240V (50/60Hz) |
Battery type | Rechargeable Li-polymer battery, 7.4V/ 5000 mAh |
Battery operation time | >4 hours @ 25ml/h |
Charging time | 8 h~12 h |
Classification | CF, Class I |
IP Grade | IPX2 |
Temperature | +5~+40 °C for operating, -30 °C~+55 °C for storage |
Humidity | 20~90% for operating, 5~96% for storage |
Air pressure | 57~106 kPa for operating, 50~106kPa for storage |
Infusion set | Applicable to GB 8368-2005 disposals; diameters Φ3.5-4.3mm, |
Alam Functions | Infusion completion,KVO state, Low battery, No power, pressure failure, air bubble, open door, occlusion, infusion remider and motor failure. |
Display Information | Flow rate,Total volume, accumulated infusion, volume, residual time. |
Weight | About 1.9 kg |
Dimension | 143.6mm×151.8mm×195.3mm |
Categories
What our Clients are Saying
The organic reviews not hoax.
Meet Us At
Booth No.: A01
13th to 15th Jun. 2024
IICC Dwarka, New Delhi, India
Booth No.: F11
19th to 21st Jun. 2024
Miami Beach Convention Center, Miami Beach, Florida, USA
Booth No.: 504C Hall 11-16
9th to 12th Jul. 2024
Bogotá, Colombia
Let's profit together!
We are looking for distributors in your area.