Spirometer Portable with Ultrasonic sensor is connected with PC to achieve accurate measuring, in various scenarios, including physical health examination, emergency, clinics and community hospitals and primary hospitals.
Technical Features :
| Spirometer Portable - Ultra Sonic | |||
|---|---|---|---|
Function: Complete Spirometry (FVC, SVC, Flow-Volume Loop MVV), Bronchial Dilation Test (pre/post dilator) |
|||
| No. | Item | Parameter | Accuracy |
| 1 | Flow range | 0 to 18L/s | ±2% or 50ml/s |
| 2 | Volume range | No limit | ±2% or 50ml |
| 3 | Resolution | F size mouthpieces | 1ml/s |
| 4 | Sample rate | 200Hz | -- |
| 5 | Resistance | <0.002kPa/L/s | -- |
| 6 | Minimum dead space | F size mouthpieces | 18mL |
| 7 | Power | <5W | -- |
| 8 | Power supply voltage | DC 5V | -- |
| 9 | Volume calculation Principle | Flow integral | -- |
| 10 | Volume resolution | 1mL | -- |
Technical Features :
| Spirometer - Expert | |||
|---|---|---|---|
Function: Complete Spirometry (Slow VC, FVC, Flow-Volume Loop, Tidal FVL, MVV), Bronchial dilation test (pre/post dilator), Bronchial provocation test procedure( without hardware) |
|||
| No. | Item | Parameter | Accuracy |
| 1 | Flow range | 0 to ±2.00 L/s 0 to ±5.00 L/s 0 to ±18.00L/s |
±2% or 50ml/s ±2% or 50ml/s ±2% or 50ml/s |
| 2 | Volume range | No limit | ±2% or 50ml |
| 3 | Resolution | F size mouthpieces M size mouthpieces S size mouthpieces |
1ml/s 1ml/s 1ml/s |
| 4 | Sample rate | 200Hz | -- |
| 5 | Resistance | <0.002kPa/L/s | -- |
| 6 | Minimum dead space | F size mouthpieces M size mouthpieces S size mouthpieces |
18mL 7mL 2mL |
| 7 | Power | 300VA | -- |
| 8 | Power supply voltage | a.c. 220V | -- |
| 9 | Volume calculation Principle | Flow integral | -- |
| 10 | Volume resolution | 1mL | -- |
Technical Features :
AN759 SPIROMETER DLCO from No. 1-12
AN759-P SPIROMETER DLCO PRO from No. 1-14
| No. | Model | Parameters | Accuracy |
|---|---|---|---|
| 1 | Flow range | 0~18L/s | ±3% or ±0.08 L/s, whichever is greater |
| 2 | Volume range | 0~30 L | ± 3% |
| 3 | Resolution | S, M, F I, F II | 1ml/s |
| 4 | Sample frequency | 200Hz | / |
| 5 | Air resistance | < 0.35kPa/(L/s) | / |
| 6 | Min dead space | S M F I |
2ml 7ml 18ml |
| 7 | Power | 300VA | / |
| 8 | Supply voltage | a.c.220V | / |
| 9 | Volume calculation | Flow integrating | / |
| 10 | Volume resolution | 1mL | / |
| 11 | CO sensor | 0~0.3% | ±1% or ±50ppm, whichever is greater |
| 12 | Methane sensor | 0~0.3% | ±1% or ±50ppm, whichever is greater |
| 13 | Medication triggers inspiratory flow | Flow range::0~3L/s | ±10% |
| 14 | Equivalent volume particle size distribution | Atomization Granule diameter 1μm~5μm | > 60% |
Technical Features :
AN759 SPIROMETER DLCO from No. 1-12
AN759-P SPIROMETER DLCO PRO from No. 1-14
| No. | Model | Parameters | Accuracy |
|---|---|---|---|
| 1 | Flow range | 0~18L/s | ±3% or ±0.08 L/s, whichever is greater |
| 2 | Volume range | 0~30 L | ± 3% |
| 3 | Resolution | S, M, F I, F II | 1ml/s |
| 4 | Sample frequency | 200Hz | / |
| 5 | Air resistance | < 0.35kPa/(L/s) | / |
| 6 | Min dead space | S M F I |
2ml 7ml 18ml |
| 7 | Power | 300VA | / |
| 8 | Supply voltage | a.c.220V | / |
| 9 | Volume calculation | Flow integrating | / |
| 10 | Volume resolution | 1mL | / |
| 11 | CO sensor | 0~0.3% | ±1% or ±50ppm, whichever is greater |
| 12 | Methane sensor | 0~0.3% | ±1% or ±50ppm, whichever is greater |
| 13 | Medication triggers inspiratory flow | Flow range::0~3L/s | ±10% |
| 14 | Equivalent volume particle size distribution | Atomization Granule diameter 1μm~5μm | > 60% |
Application:
Spirometer is used to assess how well your lungs work by measuring how much air you inhale / exhale and how quickly you exhale. It is used to diagnose asthma, chronic obstructive pulmonary disease (COPD) and other conditions that affect breathing.
Basic Features:
Technical Features :
| Display Screen | Diagonal line 5.7inches |
| Monochrome LCD | |
| Resolution 320*240 | |
| Measuring range | Capacity range: 0L ~ 9L Flow velocity range: 0 ~ 14L / s |
| Accuracy | Capacity: 0L ~ 1.6L (±50ml) 6L ~ 9L (±3%) |
| Flow rate: 5% or 0.2L / s | |
| Respiratory rate: 4 / 20 ~ / min (±1 / min) 20 / 60 / min (error: ± 5%) | |
| Measuring time limit and degree | Vital capacity: every 50s, measuring 3 |
| FVC: per second, 25s, measuring 3 | |
| The maximum ventilation volume: every 12 seconds, measuring 3 | |
| Packing size | 2 Kg, 284*209*84mm |
| Optional | Software to connect to PC |
Complete, Modular Pulmonary Function System
The base unit includes spirometry, closed circuit helium dilution, functional residual capacity (FRC) and lung sub-divisions along with a CO2 scrubber and circulating fans. The 12-litre spirometer with a true volume displacement horizontal dry rolling seal is completely user accessible for easy maintenance and cleaning.
Basic Spirometry: (with option for every test to use either the closed circuit or the open circuit) Includes Forced Vital Capacity, Slow Vital Capacity, Maximum Voluntary Ventilation and Minute Tidal Ventilation including broncho challenge testing software.
Lung Volumes Methods (FRC, VC, IC, ERV, RV, TLC)
Unique: He Dilution Wash-in with standard method and closed circuit by unique low resistance dry rolling seal spirometer He dilution technique with O2 compensation and CO2 absorption.
Choice of Three DLCO Options
Unique: Medisoft is the only manufacturer featuring a choice of three diffusion methods.
Additional Options to Complete Your Pulmonary Diagnostic Testing
Bronchoprovocation and Special Resistance Testing:
Technical Specifications
| Power Requirements | 230 VAC 50 Hz | |
| Power Consumption | +/- 110 VA (module) | |
| Warm up Time | 20 minutes | |
| Meets All Electrical Safety Requirements | IEC60601-1 CE MDD 93/42/EC, Class IIa | |
| Computer Interfacing | Windows 7 Pro / Ultimate / 8.0 / 8.1 ™ Serial interface RS232 | |
| AMBIENT CONDITIONS | ||
| Temperature | 15 - 35°c | |
| Relative Humidity | 30 to 80 % | |
Product Description
The spirometer is a high-quality medical device that measures your maximum possible exhalation which is called "peak flow" (referred to in medical terms as PEF-Peak Expiratory Flow) and "forced expiratory volume" (commonly known as FEV1) in first second. Regular monitoring of your peak flow is extremely useful for controlling disease of the airways such as asthma.C.O.P.D or chronic bronchitis.
Product Features
Product Parameters
| Parameter | Specification |
| Measuring Parameters | PEF, FEV1 |
| Measuring Method | Rotating wing wheel |
| Measuring Range | Volume: 0.01 L – 9.99 L |
| Flow: 50 L/min – 900 L/min | |
| Accuracy | Volume: ±3% or ±0.05 L, whichever is greater |
| Flow: ±10% or ±20 L/min, whichever is greater |