Dialysis Consumables

DC1001 : Polyethersulfone (PES) Dialyzer (High Flux Dialyzer)
Model and Specification DC1001 DC1002 DC1003 DC1004 DC1005 DC1006
Membrane Material Medical-grade polyether sulfone (PES)
Housing & Blood caps Material Medical-grade Polycarbonate (PC)
Potting Sealants Material Bi-component polyurethane sealants(PU)
Inner diameter of membrane (μm) 200
Wall thickness of membrane (μm) 40
Max. operation pressure (kPa/mmHg) 66.5/500
Max. flow rate (mL/min) Max. QB = 500mL/min, Max. QD = 500~800mL/min
Effective membrane area (m2) 1.0 1.2 1.4 1.6 1.8 2.0
UFR(mL/h*mmHg) 40 45 50 55 60 65
Blood compartment Volume (ml) 70 78 85 98 110 125
Clearance rate Test condition QB = 200mL/min
Urea 189 192 194 196 197 198
Creatinine 181 185 188 191 194 196
Phosphate 176 180 184 188 192 195
Vitamin B12 105 124 137 150 162 175
Inulin 65 78 94 107 120 130
Test condition QB = 300mL/min
Urea 248 255 262 270 276 280
Creatinine 225 235 243 250 256 262
Phosphate 224 230 236 242 248 254
Vitamin B12 128 142 156 170 183 196
Inulin 90 98 110 120 128 134
Test Condition QB = 400mL/min
Urea - 297 306 315 324 330
Creatinine - 274 282 290 297 304
Phosphate - 260 270 280 290 298
Vitamin B12 - 154 170 185 198 212
Inulin - 110 118 128 136 142
Sieving coefficient Test condition QB = 300mL/min,QF = 65mL/min
Albumin(%) ≤1
Inulin(%) 90±10
Myoglobin(%) 55±10
β2 -microglobulin(%) 70±10
Sterilization ɣ-rays

Note: Vitro performance parameter condition for UFR: Q=200mL/min, TMP=100mmHg, T=37°C, test by anticoagulation bovine plasma, total protein content 60 5g/l. Vitro performance parameter condition for clearance rate: Q=500mL/min Q=10mL/min T=37°C test by simulated body fluid (EN 1283) BDF


DC2001 : Polyethersulfone (PES) Dialyzer (Low Flux Dialyzer)
Model and Specification DC2001 DC2002 DC2003 DC2004 DC2005 DC2006
Membrane Material Medical-grade polyether sulfone (PES)
Housing & Blood caps Material Medical-grade Polycarbonate (PC)
Potting Sealants Material Bi-component polyurethane sealants(PU)
Inner diameter of membrane (μm) 200
Wall thickness of membrane (μm) 40
Max. operation pressure (kPa/mmHg) 66.5/500
Max. flow rate (mL/min) Max. QB = 500mL/min, Max. QD = 500mL/min
Effective membrane area (m2) 1.0 1.2 1.4 1.6 1.8 2.0
UFR(mL/h*mmHg) 15 18 22 25 28 30
Blood compartment Volume (ml) 70 78 85 98 110 125
Clearance rate Test condition QB = 200mL/min
Urea 186 188 190 192 194 196
Creatinine 175 178 181 184 187 190
Phosphate 165 170 175 180 185 189
Vitamin B12 88 100 110 118 126 133
Test condition QB = 300mL/min
Urea 238 245 252 260 267 275
Creatinine 206 220 233 245 257 270
Phosphate 192 203 214 225 235 245
Vitamin B12 92 104 120 136 150 165
Test Condition QB = 400mL/min
Urea - 268 279 290 300 312
Creatinine - 248 261 275 288 300
Phosphate - 230 244 257 270 283
Vitamin B12 - 110 125 142 158 173
Sterilization ɣ-rays

Note: Vitro performance parameter condition for UFR: Q=100mL/min, TMP=100mmHg, T=37°C, test by anticoagulation bovine plasma, total protein content 60 5g/l. Vitro performance parameter condition for clearance rate: Q=500mL/min Q=10mL/min T=37°C test by simulated body fluid (EN 1283) BDF


DC1000 : Bloodline

Standard Features:

All tubes are made from medical grade, all components are manufactured in original.

  • Pump Tube: With high elasticity and medical grade PVC, the shape of tube remains the same after continuous pressing of 10 hours.
  • Drip Chamber: Several sizes of drip chamber available.
  • Dialysis Connector: Extra large designed dialyzer connector is easy to operate.
  • Clamp: Clamp is made of hard plastic and designed larger and thicker to gurantee sufficient stop.
  • Infusion Set: It is convenient to install and uninstall, which ensure precision infusion and safe priming.
  • Drainage Bag: Closed priming to meet the requirements of quality control, single way drainage bag and double way drainage bag available.
  • Customized Designed: Different sizes of pump tube and chamber to meet the requirements of customers.
  • IV set, drainage bag, transducer protectors and other accessories can be added according to the needs of clinical use.

DC2000 : Hemodialysis Catheter Kits

Standard Features:

  • Disposable hemodialysis catheter kit for short term;
  • Double lumen;
  • Straight and curved are both available

DC3000 : Arterial-Venous Fistula Needles

Standard Features:

  • 15G, 16G, 17G;
  • Soft tube with anti-kinking properties;
  • Fixed and rotating wing available for easy operation.

Categories



What our Clients are Saying

The organic reviews not hoax.


Meet Us At


Africa Health Exhibition 2024

Booth: H2.D10
22nd to 24th Oct. 2024
Cape Town International Convention Centre, South Africa

MEDICA 2024

Hall 10/A74
11th to 14th Nov. 2024
Düsseldorf, Germany.

Arab Health 2025

27th to 30th Jan. 2025
on Concourse Near Ibis Hotel, Dubai World Trade Centre, Dubai, UAE.

Become Our Distributor

Let's profit together!
We are looking for distributors in your area.

Dialysis Consumables - Manufacture and Exporters of Polyethersulfone (PES) Dialyzer, Bloodline, Hemodialysis Catheter Kits, Arterial-Venous Fistula Needles, I.V. Start Kit, Radiology Procedure Pack, Minor Surgical Kit, Spinal Set, Swabbing Set, Dental Kit, Basic Procedure Pack, Procedure Pack, Catheterization Set, Dialysis Set, Suture Set, Suture Removal Set, Manufacturer, India. Trust NET brand for Surgical Instruments, Medical Supplies, Hospital Equipments, Laboratory Products & Goods.

Narang Medical Limited

Narang Tower, 46 Community Centre, Naraina Ph-I, New Delhi - 110028, India.

Call us: +91-11-45554000

Mail Us: NET@narang.com

Associate Sites


© Narang Medical Limited. All Rights Reserved

Narang Medical Reviews

Dialysis Consumables

Dialysis Consumables Suppliers

Dialysis Consumables Manufacturer

Dialysis Consumables India